We have developed a disposable microfluidic chip with integrated cavity mirrors comprised of two pieces of 3M Vikuiti™ enhanced specular reflector II (ESRII) film, for performing cavity-enhanced absorption spectroscopy with a white light-emitting diode (LED). Compared to measurements made with a chip without cavity mirrors, the absorption path length is enhanced by a maximum factor of 28 at 544 nm, and the sensitivity is enhanced by approximately 5 times, enabling micromolar range detection limits to be achieved in an optical path length of only 50 μm.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c4lc01264jDOI Listing

Publication Analysis

Top Keywords

cavity-enhanced absorption
8
absorption spectroscopy
8
spectroscopy white
8
white light-emitting
8
light-emitting diode
8
cavity mirrors
8
path length
8
on-chip cavity-enhanced
4
diode polymer
4
polymer mirrors
4

Similar Publications

Detection of trace gases, such as radioactive carbon dioxide, clumped isotopes, and reactive radicals, is of great interest and poses significant challenges in various fields. Achieving both high selectivity and high sensitivity is essential in this context. We present a highly selective molecular spectroscopy method based on comb-locked, mid-infrared, cavity-enhanced, two-photon absorption.

View Article and Find Full Text PDF

Nitrous acid (HONO) is crucial in atmospheric chemistry as it is a major precursor for hydroxyl radicals (OH), the dominant atmospheric oxidant. Hydroxyl radicals are essential in the formation of secondary air pollutants like ozone and particulate matter. This study presents a newly developed Incoherent Broadband Cavity Enhanced Absorption Spectroscopy (IBBCEAS) system for precise and rapid measurements of HONO and nitrogen dioxide (NO) emissions.

View Article and Find Full Text PDF

It remains unclear how the collective strong coupling of cavity-confined photons to the electronic transitions of molecular chromophore leverages the distinct properties of the polaritonic constituents for future technologies. In this study, we design, fabricate, and characterize multiple types of Fabry-Pérot (FP) mirco-resonators containing copper(II) tetraphenyl porphyrin (CuTPP) to show how cavity polariton formation affects radiative relaxation processes in the presence of substantial non-Condon vibronic coupling between two of this molecule's excited electronic states. Unlike the prototypical enhancement of Q state radiative relaxation of CuTPP in a FP resonator incapable of forming polaritons, we find the light emission processes in multimode cavity polariton samples become enhanced for cavity-exciton energy differences near those of vibrations known to mediate non-Condon vibronic coupling.

View Article and Find Full Text PDF

Development and Field Deployment of a ppb-Level SO/NO Dual-Gas Sensor System for Agricultural Early Fire Identification.

ACS Sens

December 2024

State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, P. R. China.

Sulfur dioxide (SO) and nitrogen dioxide (NO) are chemical indicators of crop straw combustion as well as significant atmospheric pollutants. It is challenging to promptly detect natural "wildfires" during agricultural production, which often lead to uncontrollable and substantial economic losses. Moreover, both "wildfires" and artificial "straw burning" practices pose severe threats to the ecological environment and human health.

View Article and Find Full Text PDF

This study investigates the integration of Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) with High-Performance Liquid Chromatography (HPLC) to detect synthetic antioxidants; BHA, BHT, and TBHQ in the deep-UV region below 300 nm. The research addresses the need for more sensitive and cost-effective detection methods in HPLC systems, particularly for low analyte concentrations, by exploring BBCEAS as a superior alternative to conventional detectors that often fall short in sensitivity. The sensitivity of the HPLC-BBCEAS system is assessed by calculating the minimum detectable change in the absorption coefficient (αmin) and comparing with those obtained using conventional HPLC and single-wavelength HPLC-CRDS methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!