Sterile radiation reduction gloves have been widely used over the past several decades in an effort to reduce hand doses during fluoroscopically guided proce- dures. While multiple studies have quantified the potential dose reduction to the fluoroscope operator from the use of such gloves, possible effects on the patient have not yet been quantified. The aim of this study was to examine the impact on patient dose when radiation reduction gloves are used. The impact on patient dose when using radiation reduction gloves in the field of view (FOV) was evalu- ated by measuring patient entrance surface dose rates (ESDR) using three C-arm fluoroscopes for a range of patient sizes and different operating and magnification modes. Multiple measuring fields were used in combination with both peripheral and central glove placement. ESDR were measured with no glove in the FOV, with one radiation reduction glove, and with double gloves in the FOV, to replicate the actions of some fluoroscope operators. Compared to an ungloved hand, the use of a single radiation reduction glove in the measuring field resulted in up to a 2.8-fold increase in ESDR. The use of double radiation reduction gloves resulted in up to a 4.9-fold increase in ESDR. In both cases, the increase in ESDR was dependent on the size of the patient and on the operating and magnification modes used, and ranged from no increase up to the aforementioned maximum. When used in the FOV, and particularly within the measuring field, radiation reduction gloves can substantially increase ESDR. This increase in dose, when considered against the relatively small published reduction in dose to the operator's hands, may mean that the increased risks from the use of radiation reduction gloves outweigh the benefits. In any case, hands should not be placed in the FOV if not required by the goals of the procedure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711104 | PMC |
http://dx.doi.org/10.1120/jacmp.v15i6.5002 | DOI Listing |
Spine (Phila Pa 1976)
January 2025
Department of Orthopedic Surgery, Hotel Dieu de France Hospital, Beirut, LEBANON.
Study Design: Meta-Analysis.
Objective: The purpose of this systematic review and meta-analysis was to pool the available data comparing MIS to open surgery for thoracolumbar fractures and provide a more comprehensive assessment on this topic.
Background: There remains a debate over whether minimally invasive surgery (MIS) or open fixation provides superior outcomes for patients with thoracolumbar fractures.
Environ Sci Technol
January 2025
Environmental Protection Research Institute, Sinopec (Beijing) Research Institute of Chemical Industry Co., Ltd., Beijing 100013, China.
The removal of antimony from wastewater using traditional methods such as adsorption and membrane filtration generates large amounts of antimony-containing hazardous wastes, posing significant environmental threats. This study proposed a new treatment strategy to reductively remove and recover antimony from wastewater using an advanced UV/sulfite reduction process in the form of valuable strategic metalloid antimony (Sb(0)), thus preventing hazardous waste generation. The results indicated that more than 99.
View Article and Find Full Text PDFJ Environ Manage
January 2025
School of Environmental Science and Engineering, Nanjing Tech University, Nanjing, 211816, China. Electronic address:
Ofloxacin (OFX), commonly employed in the treatment of infectious diseases, is frequently detected in aquatic environments and poses potential ecological risks. UV/HO oxidation has been recognized as an efficient approach for removing antibiotics. In this study, Cu-doped waste-tire carbon was prepared and used as a UV/HO catalyst for the degradation of OFX.
View Article and Find Full Text PDFAims: To compare the effects of ipragliflozin, a sodium-dependent glucose transporter-2 inhibitor, and those of metformin on the visceral fat area (VFA), a prospective, multi-centre, open-label, blinded-endpoint, randomized, controlled study was undertaken. The generated data were used to examine the effects of ipragliflozin and metformin on indices of hepatic steatosis and liver fibrosis.
Materials And Methods: In total, 103 Japanese patients with type-2 diabetes (T2D), body mass index (BMI) of ≥22 kg/m and glycated haemoglobin level of 7%-10% were randomly administered ipragliflozin 50 mg or metformin 1000 mg for 24 weeks.
Sci Rep
January 2025
Engineering Research Center of Flexible Radiation Protection Technology, Universities of Shaanxi Province, Xi'an Polytechnic University, Xi'an, 710048, Shaanxi, China.
The impact of light radiation, a predominant energy release mechanism in nuclear explosions, on material properties is of critical importance. This investigation employed an artificial light source to replicate the effects of nuclear explosion radiation and utilized a physical information neural network (PINN) to examine the temperature evolution and corresponding changes in the mechanical properties of carbon fiber/epoxy composites (CFEC). A light source simulating nuclear explosion's light radiation was built to irradiate the CFEC, then measure the reflection spectrum and temperature of samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!