The purpose of this study is to evaluate dosimetric errors in 3D conventional plan- ning of stereotactic body radiotherapy (SBRT) by using a 4D deformable image registration (DIR)-based dose-warping and integration technique. Respiratory- correlated 4D CT image sets with 10 phases were acquired for four consecutive patients with five liver tumors. Average intensity projection (AIP) images were used to generate 3D conventional plans of SBRT. Quasi-4D path-integrated dose accumulation was performed over all 10 phases using dose-warping techniques based on DIR. This result was compared to the conventional plan in order to evalu- ate the appropriateness of 3D (static) dose calculations. In addition, we consider whether organ dose metrics derived from contours defined on the average intensity projection (AIP), or on a reference phase, provide the better approximation of the 4D values. The impact of using fewer (< 10) phases was also explored. The AIP- based 3D planning approach overestimated doses to targets by 1.4% to 8.7% (mean 4.2%) and underestimated dose to normal liver by up to 8% (mean -5.5%; range -2.3% to -8.0%), compared to the 4D methodology. The homogeneity of the dose distribution was overestimated when using conventional 3D calculations by up to 24%. OAR doses estimated by 3D planning were, on average, within 10% of the 4D calculations; however, differences of up to 100% were observed. Four-dimensional dose calculation using 3 phases gave a reasonable approximation of that calculated from the full 10 phases for all patients, which is potentially useful from a workload perspective. 4D evaluation showed that conventional 3D planning on an AIP can significantly overestimate target dose (ITV and GTV+5mm), underestimate normal liver dose, and overestimate dose homogeneity. Implementing nonadaptive quasi- 4D dose calculation can highlight the potential limitation of 3D conventional SBRT planning and the resultant misrepresentations of dose in some regions affected by motion and deformation. Where the 4D approach is unavailable, contouring on the full expiration phase may yield more accurate dose calculations, most relevant in the case of the healthy liver, but the absolute dose differences are in general small for the other healthy organs. The technique has the potential to quantify under- and over-dosage and improve treatment plan evaluation, retrospective plan analysis, and clinical outcome correlation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5711129 | PMC |
http://dx.doi.org/10.1120/jacmp.v15i6.4978 | DOI Listing |
J Radiol Prot
January 2025
Department of Biostatistics, Soon Chun Hyang University Hospital Bucheon, Bucheon, Gyeonggi-do, Korea (the Republic of).
This study investigated the additional radiation exposure, influencing factors, and clinical significance of overlapping Z-axis coverage in abdominopelvic CT scans performed consecutively after same-day chest CT scans. Data from 761 patients were analyzed, with measuring the total and overlapping Z-axis coverage of the portal venous phase in abdominopelvic CT scans. The average overlapping portion was 33.
View Article and Find Full Text PDFAnnu Rev Immunol
January 2025
3Department of Environmental Medicine and Department of Microbiology and Immunology, University of Rochester, Rochester, New York, USA; email:
Initially discovered for its role mediating the deleterious effects of environmental contaminants, the aryl hydrocarbon receptor (AHR) is now known to be a crucial regulator of the immune system. The expanding list of AHR ligands includes synthetic and naturally derived molecules spanning pollutants, phytochemicals, pharmaceuticals, and substances derived from amino acids and microorganisms. The consequences of engaging AHR vary, depending on factors such as the AHR ligand, cell type, immune challenge, developmental state, dose, and timing of exposure relative to the immune stimulus.
View Article and Find Full Text PDFBlood
January 2025
Tongji Hospital, Tongji University School of Medicine, Shanghai, China.
Prizloncabtagene autoleucel (prizlon-cel), a novel bispecific chimeric antigen receptor (CAR) T-cell, targets and eliminates CD19/CD20 positive tumor cells. This phase 1, open-label study investigated the safety and efficacy of prizlon-cel in patients with relapsed/refractory B-cell non-Hodgkin Lymphoma (r/r B-NHL). Patients with CD19 and/or CD20-positive r/r B-NHL received a 3-day lymphodepletion (cyclophosphamide: 300 mg/m2/d; fludarabine: 30 mg/m2/d) followed by an intravenous dose of prizlon-cel.
View Article and Find Full Text PDFN Engl J Med
January 2025
From the Department of Medicine, University of Auckland, Auckland, New Zealand (M.J.B., Z.N., A.M., C.G., V.P., B.M., A.G., I.R.R., G.G., A.H.); the Department of Psychology, Stanford University, Stanford, CA (C.G.); and the Department of Radiology, Starship Hospital, Auckland, New Zealand (S.B.).
Background: Zoledronate prevents fractures in older women when administered every 12 to 18 months, but its effects on bone density and bone turnover persist beyond 5 years. Whether infrequent zoledronate administration would prevent vertebral fractures in early postmenopausal women is unknown.
Methods: We conducted a 10-year, prospective, double-blind, randomized, placebo-controlled trial involving early postmenopausal women (50 to 60 years of age) with bone mineral density T scores lower than 0 and higher than -2.
AJR Am J Roentgenol
January 2025
Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Phoenix, AZ.
Contrast-enhanced mammography (CEM) is growing in clinical use due to its increased sensitivity and specificity compared to full-field digital mammography (FFDM) and/or digital breast tomosynthesis (DBT), particularly in patients with dense breasts. To perform an intraindividual comparison of MGD between FFDM, DBT, a combination protocol using both FFDM and DBT (combined FFDM-DBT), and CEM, in patients undergoing breast cancer screening. This retrospective study included 389 women (median age, 57.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!