Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural similarities to amphetamines and phencyclidine (PCP) have the potential to cross-react with assays designed to detect these compounds. This study evaluates the cross-reactivity of five commercially available immunoassay reagent kits for 94 designer drugs on a Roche/Hitachi Modular P automated screening instrument. The compounds used in this study are grouped by structural class as follows: 2,5-dimethoxyamphetamines, 2C (2,5-dimethoxyphenethylamines), β-keto amphetamines, substituted amphetamines, piperazines, α-pyrrolidinopropiophenones, tryptamines and PCP analogs. A drug concentration of 100 µg/mL was used to determine cross-reactivity for each assay and resulted in the following positive rates: Microgenics DRI(®) Ecstasy enzyme assay (19%), Microgenics DRI(®) Phencyclidine enzyme assay (20%), Lin-Zhi Methamphetamine enzyme immunoassay (39%), Siemens/Syva(®) EMIT(®)II Plus Amphetamines assay (43%) and CEDIA(®) DAU Amphetamine/Ecstasy assay (57%). Of the 94 designer drugs tested, 14% produced a negative response for all five kits. No designer drug used in this study generated a positive result for all five immunoassay kits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jat/bku133 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!