Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A miniaturized transverse flow gating interface (μ-TFGI) is presented for the on-line coupling of solid-phase extraction with capillary electrophoresis (SPE-CE). The fabrication and operation procedures of the μ-TFGI are described in detail. After the operation conditions were investigated and selected, the μ-TFGI was evaluated on an SPE-CE-UV setup using clenbuterol (CLB) as the test analyte. The preconcentration factors obtained with the SPE-CE-UV system and the SPE-UV part were 600 and 620, respectively. The plate numbers obtained within 3 min were 100000 and 80000 for automatic injection via the μ-TFGI and manual direct injection, respectively. The precisions were 2.4 - 6.8% (RSD, %, n = 9) and 3.1% (RSD, %, n = 27) for the recovery (94.3 - 101.9%) and migration time of CLB spiked in urine samples, respectively. These results demonstrate that the μ-TFGI has the ability to exactly and reproducibly transfer nanoliters of fractions from SPE onto CE with no degradation of the efficiencies of SPE and CE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2116/analsci.30.1151 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!