A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Results of "elephant trunk" total aortic arch replacement using a multi-branched, collared graft prosthesis. | LitMetric

Results of "elephant trunk" total aortic arch replacement using a multi-branched, collared graft prosthesis.

Heart Vessels

Division of Cardiac Surgery, Department of Cardiothoracic Surgery, Universitätsklinikum Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany.

Published: March 2016

We report on our experience with a simplified elephant trunk (ET) procedure with a multi-branched prosthesis (Vascutek(®) Siena™ Collared Graft). It consists of a proximal portion (20 cm) with prefabricated side branches, a collar and a distal portion (30 cm). The collar, which can be trimmed into any desired diameter, constitutes the suture portion to the descending aorta. Radiopaque markers in the distal portion indicate the landing zone. Between January 2011 and June 2013, 20 consecutive patients (10 women; mean age, 66 ± 9.3 years) underwent ET procedure, including 6 re-do cases. Underlying aortic diseases were acute dissection (n = 6), chronic dissection (n = 4), aneurysm (n = 8) and PAU (n = 2). Mean preoperative diameter of the descending aorta was 49.1 ± 12.9 mm (range 74.7-29.7 mm). Concomitant procedures included ascending aortic replacement in 16 patients; root replacement in 2; AVR in 2, CABG in 3 and mitral repair in 1 patient. CPB time was 263 ± 94 min; mean duration of ACP was 65 ± 14 min. Two patients died on POD 8 and 78, respectively. Major adverse events included stroke (n = 1), resternotomy for bleeding (n = 2), renal failure requiring temporary dialysis (n = 1) and recurrent nerve paresis (n = 2). After a mean follow-up of 10 ± 8 months, all discharged patients were alive. Seven patients underwent stent-graft implantation of the descending aorta and one patient underwent open descending aortic replacement. The last generation of multi-branched arch prosthesis and especially the Vascutek(®) Siena™ Collared Graft make ET procedure a reasonable treatment option even in patients with acute aortic dissection.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-014-0612-6DOI Listing

Publication Analysis

Top Keywords

collared graft
12
descending aorta
12
prosthesis vascutek®
8
vascutek® siena™
8
siena™ collared
8
distal portion
8
aortic replacement
8
patients
6
aortic
5
"elephant trunk"
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!