Purpose: We sought to test a novel, extraluminal method of intestinal lengthening that precludes violation of the intestinal wall.

Methods: Sprague-Dawley rats (n=45) with size-matched bowel segments isolated by Roux-en-Y reconstruction were divided into three groups. Group 1 (n=14) had no further manipulations. In Groups 2 (n=12) and 3 (n=19), the isolated segment was wrapped around a length-matched device in a helicoidal fashion. In Group 2, the device consisted of plain polyurethane tubing. In Group 3, it consisted of a gradually expanding hygroscopic hydrogel (12.5mm final diameter). Euthanasia was performed at 8-21 days. Statistical analysis was by two-way ANOVA (P<0.05).

Results: Overall survival was 87% (39/45). There was a statistically significant increase in bowel length in Group 3 compared to the other two groups (P<0.001). This increase correlated with the number of helicoidal coils (P=0.018), but not with post-operative time (P>0.50). There were no significant differences in total DNA/protein ratio across the groups (P=0.65). Histologically, there was an apparent increase in the goblet cell density in Group 3.

Conclusions: Measured extraluminal helicoidal stretch (Helixtretch) is tolerated by the intestine. Helixtretch induces bowel lengthening in a rodent model. Further analysis of this novel, minimally invasive alternative for intestinal augmentation is warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpedsurg.2014.09.020DOI Listing

Publication Analysis

Top Keywords

method intestinal
8
intestinal lengthening
8
extraluminal helicoidal
4
helicoidal stretch
4
stretch helixtretch
4
helixtretch novel
4
novel method
4
lengthening purpose
4
purpose sought
4
sought test
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!