Computed tomographic evaluation of elbow congruity during arthroscopy in a canine cadaveric model.

Vet Comp Orthop Traumatol

Kevin J. Parsons, Department of Clinical Veterinary Sciences, University of Bristol, Langford House, Langford, Bristol, BS40 5DU, United Kingdom, Phone: +44 1179 289420, Fax: +44 1179 289628, E-mail:

Published: September 2015

Objective: To assess the effect of arthroscope insertion, using a carbon-fibre rod model, on humero-radial, humero-ulnar and radio-ulnar congruity, as assessed by computed tomography (CT).

Methods: Cadaveric Greyhound elbow joints were assessed at a flexion angle of 135 ± 5° using CT. For condition 1, a 36 mm fulcrum induced cubital valgus, as used to aid arthroscope insertion. For conditions 2 and 3, a single 1.8 or 2.5 mm diameter rod was inserted under arthroscopic guidance to simulate arthroscope position for assessment of the medial coronoid process. Repeat CT scans were obtained for all conditions and parasagittal sections were reconstructed to evaluate medial, axial and lateral positions within the elbow. Humero-radial, humero-ulnar, and radio-ulnar congruity measurements were obtained. Differences between groups were assessed using repeated measures analysis of variance.

Results: Mean (±SD) change in radio-ulnar step between conditions 1 and 3 was 0.6 ± 0.3 mm (axial), 0.8 ± 0.6 mm (medial), and 0.5 ± 0.1 mm (lateral). Insertion of rods induced a significant decrease in radio-ulnar step in all planes. Significant differences were also identified between groups for humero-radial, humero-ulnar, and radio-ulnar congruity.

Clinical Significance: Insertion of carbon-fibre rods as a model for elbow arthroscope insertion induces elbow incongruity. Changes in radio-ulnar congruity are small but the effect of arthroscope diameter should be considered when assessing elbow congruity.

Download full-text PDF

Source
http://dx.doi.org/10.3415/VCOT-14-02-0017DOI Listing

Publication Analysis

Top Keywords

arthroscope insertion
12
humero-radial humero-ulnar
12
humero-ulnar radio-ulnar
12
radio-ulnar congruity
12
elbow congruity
8
insertion carbon-fibre
8
radio-ulnar step
8
elbow
6
radio-ulnar
6
congruity
5

Similar Publications

Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures.

View Article and Find Full Text PDF

Avulsion of the triceps tendon is a rare injury accounting for less than 1% of all tendon injuries. The triceps is an extensor of the elbow and causes compromised function if left untreated. Complete ruptures should be treated with early repairs for satisfactory outcomes.

View Article and Find Full Text PDF

Tenodesis of the long head of biceps is a common shoulder surgical procedure. Tenodesis can be performed either arthroscopically or open and within the glenohumeral joint, within the bicipital groove, or below the pectoralis major tendon insertion. Arthroscopic tenodesis of the biceps tendon reduces the risk of infection.

View Article and Find Full Text PDF

Inside-out repair of meniscal tears is the gold standard surgical approach; however, its use is limited by the need for a posterior incision and neurovascular risk. In this Technical Report, we present details of the all-inside arthroscopic tie-grip approach for repairing a radial tear of the midbody of the lateral meniscus using an all-inside device (TRUESPAN) and a slotted cannula. In contrast to the inside-out approach, this technique helps reduce surgical invasiveness and provides stable fixation as the vertical mattress sutures bundle the circumferential fibers and act as rip stops for the horizontal sutures.

View Article and Find Full Text PDF

Background: Contamination of sterilized surgical instruments is not a typically suspected source of increased infection rate, especially if no abnormalities in the sterilization process are detected.

Purpose/hypothesis: The purpose of this study was to report increased infection rates after knee ligament reconstructions due to undetectable sterilization process errors leading to residual moisture, not limited to a specific surgical tool. It was hypothesized that (1) residual moisture on surgical tools due to autoclave overloading would not be detected by autoclave self-diagnostics, chemical and biological tests, or organoleptic assessment and (2) this kind of contamination may elevate infection rates, especially in knee intra-articular reconstruction procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!