Purpose: To describe the main causes of explantation of phakic intraocular lenses (PIOLs) according to the anatomical site of implantation (angle supported, iris fixated, or posterior chamber).
Methods: This multicentric, retrospective, and consecutive study sponsored by the Spanish Ministry of Health comprised a total of 240 eyes (226 patients) explanted due to PIOL complications. Clinical data of 144 angle-supported lenses, 24 iris-fixated lenses, and 72 posterior chamber lenses explanted were recorded preoperatively and postoperatively.
Results: Mean age of the patients at explantation was 46.30 ± 11.84 years (range: 25 to 80 years). The mean time between implantation and explantation was 381.14 ± 293.55 weeks (range: 0.00 to 1,551.17 weeks). It was 422.33 ± 287.81 weeks for the angle-supported group, 488.03 ± 351.95 weeks for the iris-fixated group, and 234.11 ± 4,221.60 weeks for the posterior chamber group. It was 8.10 ± 5.52 years for the angle-supported group, 9.36 ± 6.75 years for the iris-fixated group, and 4.49 ± 4.25 years for the posterior chamber group. This period of time was significantly shorter in the posterior chamber group (P < .001). Overall, the main causes of explantation were cataract formation (132 eyes, 55%), endothelial cell loss (26 eyes, 10.83%), corneal decompensation (22 eyes, 9.17%), PIOL dislocation/decentration (16 eyes, 6.67%), inadequate PIOL size or power (12 eyes, 5%), and pupil ovalization (10 cases, 4.17%). Cataract development was the cause of explantation in 51.39% of angle-supported cases, 45.83% of iris-fixated cases, and 65.28% of posterior chamber cases. Endothelial cell loss was the cause of explantation in 15.97% of angle-supported PIOLs, 8.33% of iris-fixated PIOLs, and 1.39% of posterior chamber PIOLs.
Conclusions: Cataract is the main cause of PIOL explantation, especially in posterior chamber PIOLs. In the angle-supported group, endothelial cell loss was the second cause of explantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/1081597X-20141202-01 | DOI Listing |
Ophthalmic Physiol Opt
January 2025
Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.
Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).
Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.
Zhonghua Yi Xue Za Zhi
January 2025
Ophthalmology Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou310009, China.
To develop and validate a predictive model for assessing the risk of early postoperative high intraocular pressure (HIOP) following posterior chamber intraocular lens implantation. The clinical data of patients who underwent posterior chamber intraocular lens implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine between May 2023 and April 2024 were retrospectively reviewed. Patients were divided into a modeling group and a validation group with a 7∶3 ratio using computerized random allocation.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
UCL Institute of Ophthalmology, University College London, London, UK.
Purpose: A human model able to simulate the manifestation of corneal endothelium decompensation could be advantageous for wound healing and future cell therapy assessment. The study aimed to establish an ex vivo human cornea endothelium wound model where endothelium function can be evaluated by measuring corneal thickness changes.
Methods: The human cornea was maintained in an artificial anterior chamber, with a continuous culture medium infusion system designed to sustain corneal endothelium and epithelium simultaneously.
Ann Med
December 2025
Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu City, China.
Objectives: The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures.
Methods: We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ -10D) and super-high myopia groups (< -10D).
Anat Cell Biol
January 2025
Department of Neurosurgery, Tulane Center for Clinical Neurosciences, Tulane University School of Medicine, New Orleans, LA, USA.
The sphenoidal sinus septum is one of the most important landmarks during endonasal endoscopic transsphe-noidal operations. During routine coronal sectioning of the face, we found a variant Y-shaped septum in the sphenoidal sinus of a female cadaver. This unusual septum was found between two sections (anterior and posterior sections) and located inferior to the pituitary gland.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!