A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Space-resolved 3 m normal incidence spectrometer for edge impurity diagnostics in the large helical device. | LitMetric

AI Article Synopsis

  • A new vacuum ultraviolet (VUV) spectroscopy system has been developed to analyze impurity profiles in the edge plasma of the Large Helical Device (LHD) by measuring VUV emissions in a wavelength range of 300-3200 Å.
  • The system offers high spectral resolution of 0.153 Å, enabling vertical measurements of the plasma's ergodic layer and a broader profile of the entire plasma size.
  • Initial results include obtaining ion temperature data for carbon ions (CIV) and observing poloidal flow in high-density plasma discharges, demonstrating the system's effectiveness and precision in capturing dynamic plasma characteristics.

Article Abstract

A space-resolved vacuum ultraviolet (VUV) spectroscopy using a 3 m normal incidence spectrometer has been developed to measure the impurity profile in the edge ergodic layer composed of stochastic magnetic field by which the edge plasma in the large helical device (LHD) is uniquely characterized. It vertically measures the spatial profile of VUV lines emitted from impurities in the wavelength range of 300-3200 Å. The wavelength interval, Δλ, which can be measured in a single discharge, is about 37 Å. A spectral resolution of 0.153 Å, which results from an entrance slit width of the spectrometer of 20 μm, is adopted. The vertical observation range, ΔZ, can be switched by taking a convex mirror in and out, which enables both the edge profile measurement focused on the ergodic layer and the full profile measurement covering an entire vertical size of the LHD plasma, e.g., 165 ≤ ΔZ ≤ 200 mm and 1000 ≤ ΔZ ≤ 1250 mm for the R(ax)=3.6 m configuration, respectively, which shows a slight wavelength dependence. Precise calibrations on the line dispersion, spectral resolution, vertical range of the observable region, and the spatial resolution have been performed with a unique method. As a preliminary result, the ion temperature profile is obtained for CIV at 1548.20 Å in the second order (denoted as 1548.20 × 2 Å) in high-density helium discharges in addition to the emission profile with a time resolution of 100 ms in a multitrack CCD operation mode. The poloidal flow in the ergodic layer based on the Doppler-shift measurement of CIV at 1548.20 × 2 Å is also observed in high-density hydrogen discharges.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ergodic layer
12
normal incidence
8
incidence spectrometer
8
large helical
8
helical device
8
spectral resolution
8
profile measurement
8
≤ Δz
8
Δz ≤
8
civ 154820
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!