To investigate how the dwell time deviation constraint (DTDC) parameter, applied to inverse planning by simulated annealing (IPSA) optimisation limits large dwell times from occurring in each catheter and to characterise the effect on the resulting dosimetry for prostate high dose rate (HDR) brachytherapy treatment plans. An unconstrained IPSA optimised treatment plan, using the Oncentra Brachytherapy treatment planning system (version 4.3, Nucletron an Elekta company, Elekta AB, Stockholm, Sweden), was generated for 20 consecutive HDR prostate brachytherapy patients, with the DTDC set to zero. Successive constrained optimisation plans were also created for each patient by increasing the DTDC parameter by 0.2, up to a maximum value of 1.0. We defined a "plan modulation index", to characterise the change of dwell time modulation as the DTDC parameter was increased. We calculated the dose volume histogram indices for the PTV (D90, V100, V150, V200%) and urethra (D10%) to characterise the effect on the resulting dosimetry. The average PTV D90% decreases as the DTDC is applied, on average by only 1.5 %, for a DTDC = 0.4. The measures of high dose regions in the PTV, V150 and V200%, increase on average by less than 5 and 2 % respectively. The net effect of DTDC on the modulation of dwell times has been characterised by the introduction of the plan modulation index. DTDC applied during IPSA optimisation of HDR prostate brachytherapy plans reduce the occurrence of large isolated dwell times within individual catheters. The mechanism by which DTDC works has been described and its effect on the modulation of dwell times has been characterised. The authors recommend using a DTDC parameter no greater than 0.4 to obtain a plan with dwell time modulation comparable to a geometric optimised plan. This yielded on average a 1.5 % decrease in PTV coverage and an acceptable increase in V150%, without compromising the urethral dose.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-014-0317-2DOI Listing

Publication Analysis

Top Keywords

dtdc parameter
20
dwell time
16
dwell times
16
ipsa optimisation
12
hdr prostate
12
prostate brachytherapy
12
dtdc
11
time deviation
8
deviation constraint
8
constraint dtdc
8

Similar Publications

Purpose: To evaluate the impact of dwell time deviation constraint (DTDC) on the quality of IPSA-optimized treatment plans in comparison with graphical plans using plan quality scores (PQS).

Material And Methods: Seventy optimized plans (graphical & IPSA with different DTDC values) of ten cervical cancer patients were generated. Various DVH parameters like D, V, V, V, V were compared to evaluate the impact of DTDC on target coverage and high dose regions inside target for different plans.

View Article and Find Full Text PDF

Effect of the dwell time deviation constraint on brachytherapy treatment planning for cervical cancer.

J Int Med Res

August 2021

Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu, China.

Objective: This study aimed to quantify the effect of the dwell time deviation constraint (DTDC) on brachytherapy treatment for cervical cancer.

Methods: A retrospective study was carried out on 20 patients with radical cervical cancer. The DTDC values changed from 0.

View Article and Find Full Text PDF

Purpose: High-dose rate remote afterloading brachytherapy machine and advanced treatment planning system help in getting optimum dose to tumor and low dose to normal structures. Inverse planning simulated annealing (IPSA) optimization technique has a unique feature of dwell time deviation constraint (DTDC). In this study, six IPSA-based plans having different DTDC values with routinely practiced geometric plus graphical optimization (GO + GrO) have been compared using various dosimetric parameters.

View Article and Find Full Text PDF

Purpose: High Dose Rate (HDR) remote afterloading brachytherapy machine and advanced treatment planning system have made it possible to make variations in individual dwell times across a catheter according to tumour density and for sparing normal structures. New inverse planning technique such as Inverse Planning Simulated Annealing (IPSA) has also been introduced. But very few institutions are venturing towards volume based IPSA optimised intracavitary brachytherapy.

View Article and Find Full Text PDF

Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

J Contemp Brachytherapy

June 2016

Radiation Oncology, Chris O'Brien Lifehouse, Camperdown, NSW.

Purpose: Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times.

Material And Methods: This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements.

View Article and Find Full Text PDF