The consequences of losing the ability to move a limb are traumatic. One approach that examines the impact of pathological limb nonuse on the brain involves temporary immobilization of a healthy limb. Here, we investigated immobilization-induced plasticity in the motor imagery (MI) circuitry during hand immobilization. We assessed these changes with a multimodal paradigm, using functional magnetic resonance imaging (fMRI) to measure neural activation, magnetoencephalography (MEG) to track neuronal oscillatory dynamics, and transcranial magnetic stimulation (TMS) to assess corticospinal excitability. fMRI results show a significant decrease in neural activation for MI of the constrained hand, localized to sensorimotor areas contralateral to the immobilized hand. MEG results show a significant decrease in beta desynchronization and faster resynchronization in sensorimotor areas contralateral to the immobilized hand. TMS results show a significant increase in resting motor threshold in motor cortex contralateral to the constrained hand, suggesting a decrease in corticospinal excitability in the projections to the constrained hand. These results demonstrate a direct and rapid effect of immobilization on MI processes of the constrained hand, suggesting that limb nonuse may not only affect motor execution, as evidenced by previous studies, but also MI. These findings have important implications for the effectiveness of therapeutic approaches that use MI as a rehabilitation tool to ameliorate the negative effects of limb nonuse.

Download full-text PDF

Source
http://dx.doi.org/10.1093/cercor/bhu287DOI Listing

Publication Analysis

Top Keywords

constrained hand
16
limb nonuse
12
motor imagery
8
neural activation
8
corticospinal excitability
8
sensorimotor areas
8
areas contralateral
8
contralateral immobilized
8
immobilized hand
8
hand suggesting
8

Similar Publications

Systematic evaluation of adhesives for implant fixation in multimodal functional brain MRI.

MAGMA

January 2025

Translational Research Imaging Center (TRIC), Clinic of Radiology, University of Münster, Albert-Schweitzer-Campus 1, building A16, 48149, Münster, Germany.

Objective: Invasive multimodal fMRI in rodents is often compromised by susceptibility artifacts from adhesives used to secure cranial implants. We hypothesized that adhesive type, shape, and field strength significantly affect susceptibility artifacts, and systematically evaluated various adhesives.

Materials And Methods: Thirty-one adhesives were applied in constrained/unconstrained geometries and imaged with T2*-weighted EPI at 7.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Background: The reproductive problem is an animal health-related bottleneck that constrains livestock genetic improvement efforts in tropical countries such as Ethiopia. The infectious causes of reproductive disorders are one cause of decreased reproductive efficiency. This study aimed to determine the seroprevalence to Bovine Herpesvirus-1 (BHV1), Bovine Viral Diarrhea Virus (BVDV), Neospora caninum (N.

View Article and Find Full Text PDF

Sling is Not-Inferior to Brace Immobilization Following Arthroscopic Rotator Cuff Repair: A Randomized Controlled Trial.

Arthroscopy

December 2024

Orthopaedic and Traumatology Unit, Ospedale Regionale di Lugano, EOC, 6900, Lugano, Switzerland; Faculty of Biomedical Sciences, Università della Svizzera Italiana, Via Buffi 13, 6900, Lugano, Switzerland.

Purpose: The aim of this study was to compare the safety and efficacy of immobilizing the upper limb with a brace versus a less-constrained sling in the rehabilitation after arthroscopic rotator cuff repair (ARCR), by documenting clinical and radiological results.

Methods: ARCR was performed in 110 patients (54.9±8.

View Article and Find Full Text PDF

Trace amount of taurine leveling agent for stable Zn anode.

RSC Adv

December 2024

Guangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, School of Environmental and Chemical Engineering, Foshan University Foshan 528000 China

Aqueous zinc-ion batteries are highly praised for their cost-effectiveness, environmental friendliness, and high safety, making them an ideal choice for next-generation energy storage systems. However, the practical application of Zn metal anodes is constrained by well-known challenges such as dendrite growth and significant interfacial side reactions. This study introduces a trace amount of taurine (TAU) as a leveling additive into the electrolyte to optimize the microstructure of the electrolyte and the anode interface chemistry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!