Real-time monitoring and control of high shear wet granulation (HSWG) using process analytical technologies is crucial to process design, scale-up, and reproducible manufacture. Although significant progress has been made in real-time measurement of granule size distribution using focused beam reflectance measurement (FBRM), real-time in-line assessment of granule densification remains challenging. In this study, a drag force flow (DFF) sensor was developed and used to probe wet mass consistency in real-time. In addition, responses from FBRM and DFF sensors were compared to assess complementarity of information on granulation progress from the two probes. A placebo and a brivanib alaninate formulation were granulated with different concentrations of binder or water, respectively, while measuring granule size growth, densification, and DFF sensor response. The DFF sensor was able to quantitatively characterize with high resolution a response of wet mass consistency distinct from granule size distribution. The wet mass consistency parameter correlated well with granule densification, which was shown as a critical material attribute that correlated with tablet dissolution. In addition, application of DFF sensor to scale-up of granulation was demonstrated. These results showed the value of wet mass consistency measurement using DFF for WG monitoring and control.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jps.24233DOI Listing

Publication Analysis

Top Keywords

dff sensor
16
wet mass
16
mass consistency
16
granule densification
12
granule size
12
assessment granule
8
high shear
8
shear wet
8
wet granulation
8
placebo brivanib
8

Similar Publications

High-Magnification Object Tracking with Ultra-Fast View Adjustment and Continuous Autofocus Based on Dynamic-Range Focal Sweep.

Sensors (Basel)

June 2024

Namiki Laboratory, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba-shi 263-8522, Chiba, Japan.

Active vision systems (AVSs) have been widely used to obtain high-resolution images of objects of interest. However, tracking small objects in high-magnification scenes is challenging due to shallow depth of field (DoF) and narrow field of view (FoV). To address this, we introduce a novel high-speed AVS with a continuous autofocus (C-AF) approach based on dynamic-range focal sweep and a high-frame-rate (HFR) frame-by-frame tracking pipeline.

View Article and Find Full Text PDF

Background: Restricted weight-bearing is still used after lower extremity fracture surgery in elderly patients. The long-term effect on gait recovery in elderly patients with distal femur fractures (DFF) and their ability to comply with the restrictive weight-bearing regime is unknown. This study aimed to investigate the effect of restricted postoperative weight-bearing on gait recovery (actual weight-bearing and cadence) during a 1-year follow-up.

View Article and Find Full Text PDF

Recycling of phosphorus (P) from waste streams in agriculture is essential to reduce the negative environmental effects of surplus P and the unsustainable mining of geological P resources. Sewage sludge (SS) is an important P source; however, several issues are associated with the handling and application of SS in agriculture. Thus, post-treatments such as pyrolysis of SS into biochar (BC) could address some of these issues.

View Article and Find Full Text PDF

Machine learning for optical chemical multi-analyte imaging : Why we should dare and why it's not without risks.

Anal Bioanal Chem

June 2023

Aarhus University Centre for Water Technology (WATEC), Department of Biology, Section for Microbiology, Aarhus University, Ny Munkegade 114, 8000, Aarhus C, Denmark.

Simultaneous sensing of metabolic analytes such as pH and O is critical in complex and heterogeneous biological environments where analytes often are interrelated. However, measuring all target analytes at the same time and position is often challenging. A major challenge preventing further progress occurs when sensor signals cannot be directly correlated to analyte concentrations due to additional effects, overshadowing and complicating the actual correlations.

View Article and Find Full Text PDF
Article Synopsis
  • This study develops a method to estimate the amount of 1,5-diaminopentane (cadaverine) adsorbed on a microcantilever sensor by analyzing its resonance frequency in relation to known added masses.
  • This research builds on earlier work related to an electronic nose designed to assess the freshness of meat and fish by detecting cadaverine levels.
  • Through theoretical and experimental analyses, the resonance frequency response to differing cadaverine concentrations was used to create a polynomial model capable of estimating the mass of cadaverine adsorbed on the sensor.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!