A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of corneal deformation analyzed with a Scheimpflug based device. | LitMetric

Evaluation of corneal deformation analyzed with a Scheimpflug based device.

Cont Lens Anterior Eye

Multidisciplinary Department of Medical, Surgical and Dental Sciences, Second University of Naples, Naples, Italy.

Published: April 2015

Purpose: To evaluate the correlation between corneal biomechanical and morphological data in healthy eyes.

Methods: A complete clinical eye examination of naïve eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Linear regression between central corneal thickness (CCT), corneal volume (CV) and anterior corneal curvature measured with Sim'K (SK), versus corneal deformation parameters measured with Corvis ST have been run using SPSS software version 18.0.

Results: Seventy-six eyes of 76 healthy subjects (44 women and 32 men) with a mean age of 36.84 ± 10.74 years and a mean refractive error of -0.55 ± 1.68 D (measured as spherical equivalent) were evaluated. Corneal deformation parameters were weakly correlated with corneal morphological parameters and with spherical equivalent. Although the correlations between deformation amplitude versus SK and between SK versus Velocity of Applanation 2, were higher than the others (R(2) = 0.28 and 0.26 respectively), none of them was statistically significant (p>0.01).

Conclusions: According with these findings, Corvis ST seems to be able to provide an analysis of corneal deformation independent from corneal morphological characteristics. If these data will be confirmed in further studies, this device could be useful in the management and screening of eyes with corneal diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2014.10.002DOI Listing

Publication Analysis

Top Keywords

corneal deformation
16
corneal
10
oculus wetzlar
8
wetzlar germany
8
deformation parameters
8
spherical equivalent
8
corneal morphological
8
deformation
5
evaluation corneal
4
deformation analyzed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!