Adverse reactions to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron alloy stem.

J Arthroplasty

Department of Trauma and Orthopaedic Surgery, NHS Tayside, Scotland, UK; Department of Trauma and Orthopaedic Surgery, School of Medicine, University of Dundee, Scotland, UK.

Published: February 2015

We report a series of three patients who underwent uncemented total hip arthroplasty with a modular titanium-molybdenum-zirconium-iron stem and a cobalt-chrome-molybdenum head on an ultra-high molecular weight highly cross-linked polyethylene liner bearing. All three cases subsequently developed pain and adverse reaction to metal debris, leading to revision of the implants within thirty-six months. They were subsequently found to have hypersensitivity to cobalt or chromium. However where tested, blood metal ion levels were within MHRA guideline limits. Corrosion was noted at the taper-trunnion junction. It is possible, that the multi alloy head-neck combination may lead to corrosion. Hypersensitivity to metal ions may result to ARMD at lower metal ion levels. The use of ceramic heads may help avoid this risk.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2014.06.030DOI Listing

Publication Analysis

Top Keywords

metal debris
8
total hip
8
hip arthroplasty
8
metal ion
8
ion levels
8
metal
5
adverse reactions
4
reactions metal
4
debris metal-on-polyethylene
4
metal-on-polyethylene total
4

Similar Publications

The treatment for osteoarthritis (OA) often requires total joint arthroplasty (TJA) when less invasive approaches fail. The annual incidence of TJA is rising. Metal-on-metal (MoM) hip and knee implants were widely used for TJA in the past, but complications have led to their decline.

View Article and Find Full Text PDF

Endoscopic Step-Up Approach in Management of Necrotizing Pancreatitis.

Gastroenterol Clin North Am

March 2025

Department of Gastroenterology, Asian Institute of Gastroenterology, AIG Hospitals, Hyderabad, India. Electronic address:

The endoscopic step-up approach in the management of necrotizing pancreatitis involves sequential steps of intervention at different time points in the clinical course of the disease. EUS -guided drainage of walled-off necrosis is the first step of the endoscopic step-up approach. Lumen-apposing metal stents are preferred over plastic stents for safe and effective drainage because of their wide caliber.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

Characterizing molten corium-concrete interaction (MCCI) fuel debris in Fukushima reactors is essential to develop efficient methods for its removal. To enhance the accuracy of microscopic observation and focused ion beam (FIB) microsampling of MCCI fuel debris, we developed a three-dimentional FIB scanning electron microscopy (SEM) technique with a multiphase positional misalignment (MPPM) correction method. This system automatically aligns voxel positions, corrects contrast, and removes artifacts from a series of over 500 SEM images.

View Article and Find Full Text PDF

This research centers around cast steel 20Mn, which is the material utilized for the ear-picking roller of a corn harvester. The study delves into methods of enhancing its hydrophobicity and wear resistance. Fiber laser-processing technology was employed to fabricate pangolin bionic micro-textures on the material surface, and PVD technology was utilized to deposit a TiN coating.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!