Automatic measurement of pennation angle and fascicle length of gastrocnemius muscles using real-time ultrasound imaging.

Ultrasonics

Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China. Electronic address:

Published: March 2015

Muscle imaging is a promising field of research to understand the biological and bioelectrical characteristics of muscles through the observation of muscle architectural change. Sonomyography (SMG) is a technique which can quantify the real-time architectural change of muscles under different contractions and motions with ultrasound imaging. The pennation angle and fascicle length are two crucial SMG parameters to understand the contraction mechanics at muscle level, but they have to be manually detected on ultrasound images frame by frame. In this study, we proposed an automatic method to quantitatively identify pennation angle and fascicle length of gastrocnemius (GM) muscle based on multi-resolution analysis and line feature extraction, which could overcome the limitations of tedious and time-consuming manual measurement. The method started with convolving Gabor wavelet specially designed for enhancing the line-like structure detection in GM ultrasound image. The resulting image was then used to detect the fascicles and aponeuroses for calculating the pennation angle and fascicle length with the consideration of their distribution in ultrasound image. The performance of this method was tested on computer simulated images and experimental images in vivo obtained from normal subjects. Tests on synthetic images showed that the method could identify the fascicle orientation with an average error less than 0.1°. The result of in vivo experiment showed a good agreement between the results obtained by the automatic and the manual measurements (r=0.94±0.03; p<0.001, and r=0.95±0.02, p<0.001). Furthermore, a significant correlation between the ankle angle and pennation angle (r=0.89±0.05; p<0.001) and fascicle length (r=-0.90±0.04; p<0.001) was found for the ankle plantar flexion. This study demonstrated that the proposed method was able to automatically measure the pennation angle and fascicle length of GM ultrasound images, which made it feasible to investigate muscle-level mechanics more comprehensively in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2014.10.020DOI Listing

Publication Analysis

Top Keywords

pennation angle
16
angle fascicle
16
fascicle length
16
length gastrocnemius
8
ultrasound imaging
8
architectural change
8
ultrasound image
8
fascicle
5
ultrasound
5
automatic measurement
4

Similar Publications

Background: Patients with essential hypertension have a high risk of muscle mass and strength decline. Ultrasound is a promising method for assessing sarcopenia. This study aimed to analyze the correlation between ultrasound and shear-wave elastography (SWE) features, and muscle mass, muscle strength, and physical performance, and to assess the clinical applicability of ultrasound in the diagnosis of sarcopenia in patients with essential hypertension.

View Article and Find Full Text PDF

Both resistance training (RT) and long-duration, high-intensity stretching induce muscular adaptations; however, it is unknown whether the modalities are complementary or redundant, particularly in well-trained individuals. A case-study was conducted on a competitive bodybuilder implementing long-duration, high-intensity stretching of the plantar flexors (60 min 6x/week for 12 weeks) in conjunction with their habitual RT. Ultrasound muscle architecture (muscle thickness [MT], fascicle length [FL], and pennation angle [PA]) measurements were collected at multiple sites at four weekly baseline sessions, six (mid) and 12 (post1) weeks following the commencement of the intervention, and a week after the intervention (post2) while isometric strength and range of motion (RoM) were obtained once at baseline, mid, post1, and post2.

View Article and Find Full Text PDF

Investigating muscle architecture in static and dynamic conditions is essential to understand muscle function and muscle adaptations. Muscle architecture analysis, primarily through extended field-of-view ultrasound imaging, offers high reliability at rest but faces limitations during dynamic conditions. Traditional methods often involve "best fitting" straight lines to track muscle fascicles, leading to possible errors, especially with longer fascicles or those with nonlinear paths.

View Article and Find Full Text PDF

Motor unit firing rate (MUFR) and pennation angle were measured concurrently in males and females from submaximal to maximal intensities. Thirty participants, (16F and 14M) performed isometric dorsiflexion contractions at 20%, 40%, 60%, 80% and 100% of maximal voluntary contraction (MVC). During each contraction, measures of MUFR were obtained via surface electromyography decomposition, and muscle fiber pennation angle and fascicle length were obtained via ultrasound.

View Article and Find Full Text PDF

Vastus lateralis muscle architecture, quality, and stiffness are determinants of maximal performance in athletes?

J Biomech

January 2025

Exercise Biochemistry Laboratory, Department of Biochemistry and Molecular Biology, Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.

Understanding intrinsic muscular adaptations more deeply can help clarify their relationships with sports performance. Therefore, the aim of this study was to determine if vastus lateralis muscle architecture, quality and stiffness can explain knee extensor maximal torque and countermovement and squat jump performance of athletes. One hundred and two athletes were evaluated based on the architecture, quality and stiffness of the vastus lateralis at rest.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!