Laser in situ keratomileusis for -6.00 to -18.00 diopters of myopia and up to -5.00 diopters of astigmatism: 15-year follow-up.

J Cataract Refract Surg

From Vissum Instituto Oftalmologico de Alicante (Alió, Soria, Abbouda) and the Division of Ophthalmology (Alió, Peña-García), Universidad Miguel Hernández, Alicante, Spain.

Published: January 2015

Purpose: To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for high myopia with or without astigmatism.

Setting: Vissum Instituto Oftalmologico de Alicante and Miguel Hernandez University, Alicante, Spain.

Design: Retrospective-prospective case series.

Methods: Laser in situ keratomileusis was performed using the Visx 20/20 excimer laser. The minimum follow-up was 15 years. The main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and corneal topography.

Results: This study included 40 patients (40 eyes) with a mean age of 51.08 years ± 6.67 (SD) (range 41 to 60 years) with high myopia (-6.00 to -18.00 diopters [D]). At 15 years, the safety index was 1.23 and the efficacy index, 0.95. During the follow-up, a significant increase in the dioptric power of all keratometric variables was detected (P≤.028, Friedman test), the most notable increase occurring between 3 months and 1 year (P≤.005). At 15 years, 46.15% of the eyes were within ±1.00 D of the attempted spherical equivalent and 64.10% were within ±2.00 D. The UDVA at 15 years was 20/25 or better in 43.59% of eyes and 20/40 or better in 64.10% of eyes. The postoperative CDVA was significantly better than preoperatively (P<.001). The postoperative complications were minor except in 1 eye in which ectasia occurred.

Conclusions: Laser in situ keratomileusis for high myopia was safe over the long term. However, significant myopic regression with time was detected. Low preoperative pachymetry and low residual stromal bed were predictors of keratometric regression.

Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2014.08.029DOI Listing

Publication Analysis

Top Keywords

laser situ
12
situ keratomileusis
12
-600 -1800
8
-1800 diopters
8
high myopia
8
years
6
laser
4
keratomileusis -600
4
diopters myopia
4
myopia -500
4

Similar Publications

On-Demand Controlled Release Multi-Drugs Delivery System for Spatiotemporally Synergizing Antitumor Immunotherapy.

Adv Sci (Weinh)

January 2025

School of Pharmaceutical Sciences, Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases, Zhengzhou University, Zhengzhou, 450001, China.

Although cytotoxic T lymphocytes (CTLs) activation combined with programmed cell death-1 (PD-1)/programmed cell death ligand-1 (PD-L1) axis blockade have emerged as an effective strategy to improve immunotherapeutic potency, it remains challenging to realize the spatiotemporal synergy of these two components. Herein, the study reports an engineered bacterial-based delivery system that can simultaneously promote CTLs infiltration and control PD-L1 binding protein (PD-L1 trap) release on demand at tumor site. The drug release button of this tumor targeting system is the specific temperature, which is accomplished by dual-modified melanin nanoparticles with photothermal conversion capacity on the engineered bacterial.

View Article and Find Full Text PDF

Patterning Planar, Flexible Li-S Battery Full Cells on Laser-Induced Graphene Traces.

Nanomaterials (Basel)

December 2024

Quantum Nano Centre, Department of Chemical Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.

Laser conversion of commercial polymers to laser-induced graphene (LIG) using inexpensive and accessible CO lasers has enabled the rapid prototyping of promising electronic and electrochemical devices. Frequently used to pattern interdigitated supercapacitors, few approaches have been developed to pattern batteries-in particular, full cells. Herein, we report an LIG-based approach to a planar, interdigitated Li-S battery.

View Article and Find Full Text PDF

A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH) and acetylene (CH). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H) filter algorithm to reduce the system noise.

View Article and Find Full Text PDF

An 83-year-old male with a history of radial keratotomy and laser-assisted in situ keratomileusis (LASIK) presented with symptoms of a non-resolving corneal ulcer in the right eye that had been present for five months. The patient was treated with antibacterial, antiviral, and antifungal medications over that period, with multiple recurrences that prompted referral to our tertiary center for management. Following a 48-hour cessation of all medications, a corneal biopsy was performed which grew .

View Article and Find Full Text PDF

Objectives: Mal-deployment of the thoracic endovascular aortic repair (TEVAR) stent graft during a frozen elephant trunk (FET) procedure for an acute type A aortic dissection (ATAAD) leads to devastating complications. We report a hemiarch replacement with TEVAR stent graft covering the aortic arch vessels salvaged through an endovascular approach.

Methods: A 69-year-old man with ATAAD in 2018, status post-hemiarch repair with TEVAR, presented in 2023 with progressive dizziness/syncope and lower extremity hypertension with inability to tolerate anti-hypertensives.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!