Introduction: Primary closure of the abdominal wall following intestinal transplantation or multivisceral transplantation could become a challenging problem in a significant number of patients.
Presentation Of Case: A 38-year-old woman with familial adenomatous polyposis (FAP) underwent a multi-visceral transplantation for short gut syndrome. She subsequently developed acute graft rejection that proved resistant to conventional treatment. She was relisted and underwent re-transplantation along with kidney transplantation. Abdominal wall closure could not be achieved because of the large size of the graft and bowel oedema. The wound was initially managed with laparostomy followed by insertion of the delayed dynamic abdominal closure (DDAC) device (Abdominal Retraction Anchor - ABRA(®) system). Continuous dynamic traction to the wound edges resulted in gradual approximation and complete closure of the abdominal wound was achieved within 3 weeks.
Discussion: Successful abdominal closure after multivisceral transplantation or isolated intestinal transplantation often requires biological mesh, vascularised flaps or abdominal wall transplantation. DDAC eliminated the need for a prosthetic mesh or skin graft and provided an excellent cosmetic result. Adjustment of the dynamic traction at the bedside minimised the need for multiple returns to the operating theatre. It resulted in a well-healed linear scar without a hernia.
Conclusion: Dynamic traction allows delayed closure of laparotomy resulting in strong and cosmetically sound wound healing with native tissue.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4276090 | PMC |
http://dx.doi.org/10.1016/j.ijscr.2014.08.006 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!