Improving the radiologist-CAD interaction: designing for appropriate trust.

Clin Radiol

Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands; Center for Medical Imaging North East Netherlands, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.

Published: February 2015

Computer-aided diagnosis (CAD) has great potential to improve radiologists' diagnostic performance. However, the reported performance of the radiologist-CAD team is lower than what might be expected based on the performance of the radiologist and the CAD system in isolation. This indicates that the interaction between radiologists and the CAD system is not optimal. An important factor in the interaction between humans and automated aids (such as CAD) is trust. Suboptimal performance of the human-automation team is often caused by an inappropriate level of trust in the automation. In this review, we examine the role of trust in the radiologist-CAD interaction and suggest ways to improve the output of the CAD system so that it allows radiologists to calibrate their trust in the CAD system more effectively. Observer studies of the CAD systems show that radiologists often have an inappropriate level of trust in the CAD system. They sometimes under-trust CAD, thereby reducing its potential benefits, and sometimes over-trust it, leading to diagnostic errors they would not have made without CAD. Based on the literature on trust in human-automation interaction and the results of CAD observer studies, we have identified four ways to improve the output of CAD so that it allows radiologists to form a more appropriate level of trust in CAD. Designing CAD systems for appropriate trust is important and can improve the performance of the radiologist-CAD team. Future CAD research and development should acknowledge the importance of the radiologist-CAD interaction, and specifically the role of trust therein, in order to create the perfect artificial partner for the radiologist. This review focuses on the role of trust in the radiologist-CAD interaction. The aim of the review is to encourage CAD developers to design for appropriate trust and thereby improve the performance of the radiologist-CAD team.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2014.09.017DOI Listing

Publication Analysis

Top Keywords

cad system
20
radiologist-cad interaction
16
cad
16
trust
12
appropriate trust
12
performance radiologist-cad
12
radiologist-cad team
12
level trust
12
role trust
12
trust cad
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!