Background: Clot lysis values (LY30) determined by rapid thrombelastography (rTEG) predict postinjury transfusion needs and mortality risk. However, the first derivative velocity curve values generated by rTEG measuring lysis—maximum rate of lysis (MRL) and total lysis (TL)—have not been evaluated. Although recent data support use of antifibrinolytics in trauma, the population that would benefit remains poorly defined. The purpose of this study was to determine if velocity curves more accurately predict large volume transfusions and early mortality than conventional rTEG values.

Study Design: Conventional and velocity curve admission rTEG values of adult trauma patients were retrospectively evaluated for their ability to predict early transfusion of RBC and plasma, substantial bleeding, massive transfusion, and mortality. Patient outcomes were compared according to hyperfibrinolysis diagnosed by velocity curve values and the conventional LY30 cutoff.

Results: There were 1,625 patients included. Clot lysis values predicted early transfusion of RBC (p = 0.003), but not plasma (p = 0.298), within 3 hours of arrival. With respect to velocity curves, MRL and TL predicted both early RBC and plasma transfusion (p < 0.05). All 3 parameters predicted massive transfusion, but only MRL and TL predicted substantial bleeding (odds ratio [OR] 3.1 and 2.9, respectively). In addition, MRL was a stronger predictor of 24-hour and 30-day mortality (p < 0.001) and was also available earlier after arrival than LY30 (p < 0.001).

Conclusions: Velocity curve measures of fibrinolysis are stronger predictors of early transfusion of blood components, bleeding, and mortality after trauma compared with conventional rTEG values. In addition, the MRL is more rapidly available after arrival, which may facilitate earlier diagnosis and treatment of clinically significant hyperfibrinolysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jamcollsurg.2014.07.943DOI Listing

Publication Analysis

Top Keywords

velocity curve
16
velocity curves
12
early transfusion
12
clinically hyperfibrinolysis
8
clot lysis
8
lysis values
8
transfusion mortality
8
curve values
8
conventional rteg
8
rteg values
8

Similar Publications

Fast Fourier Transform-based Space-Time Image Velocimetry (FFT-STIV) has gained considerable attention due to its accuracy and efficiency. However, issues such as false detection of MOT and blind areas lead to significant errors in complex environments. This paper analyzes the causes of FFT-STIV gross errors and then proposes a method for validity identification and rectification of FFT-STIV results.

View Article and Find Full Text PDF

In this paper, we demonstrate that torsional surface elastic waves can propagate along the curved surface of a metamaterial elastic rod (cylinder) embedded in a conventional elastic medium. The crucial parameter of the metamaterial rod is its elastic compliance s44(1)ω, which varies as a function of frequency ω analogously to the dielectric function εω in Drude's model of metals. As a consequence, the elastic compliance s44(1)ω can take negative values s44(1)ω<0 as a function of frequency ω.

View Article and Find Full Text PDF

Pupil responses are commonly used to provide insight into visual perception, autonomic control, cognition, and various brain disorders. However, making inferences from pupil data can be complicated by nonlinearities in pupil dynamics and variability within and across individuals, which challenge the assumptions of linearity or group-level homogeneity required for common analysis methods. In this study, we evaluated luminance evoked pupil dynamics in young healthy adults (n = 10, M:F = 5:5, ages 19-25 years) by identifying nonlinearities, variability, and conserved relationships across individuals to improve the ability to make inferences from pupil data.

View Article and Find Full Text PDF

Background: The incidence of contrast-induced acute kidney injury (CI-AKI) in the general population ranges from 0.6 to 2.3%, whereas for specific high-risk patients, the incidence can reach more than 30-40%.

View Article and Find Full Text PDF

Ambient noise cross-correlation has been widely used to observe post-earthquake temporal velocity variations. Comparative studies are essential for assessing seismic hazards and clarifying the relationship between velocity variation and magnitude. However, very few comparative studies by earthquake magnitude have been conducted, particularly for magnitudes smaller than 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!