The gradient-performance limits of capillary ion chromatography have been assessed at maximum system pressure (34.5 MPa) using capillary columns packed with 4.1 μm macroporous anion-exchange particles coated with 65 nm positively-charged nanobeads. In analogy to the van-Deemter curve, the gradient performance was assessed applying different flow rates, while decreasing the gradient time inversely proportional to the increase in flow rate in order to maintain the same retention properties. The gradient kinetic-performance limits were determined at maximum system pressure, applying tG/t0=5, 10, and 20. In addition, the effect of retention on peak width was assessed in gradient mode for mono-, di-, and trivalent inorganic anions. The peak width of late-eluting ions can be significantly reduced by using concave gradient, resulting in better detection sensitivity. A signal enhancement factor of 8 was measured for a late-eluting ion when applying a concave instead of a linear gradient. For the analysis of a complex anion mixture, a coupled column with a total length of 1.05 m was operated at the kinetic-performance limit applying a linear 250 min gradient (tG/t0=10). The peak capacity varied between 200 and 380 depending on analyte retention, and hence on charge and size of the ion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2014.10.028DOI Listing

Publication Analysis

Top Keywords

gradient
8
maximum system
8
system pressure
8
peak width
8
contemporary liquid
4
liquid chromatography
4
chromatography theory
4
theory technology
4
technology improve
4
improve capillary
4

Similar Publications

Background: Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous entity including patients with different phenotypes of near normal, normal, and supernormal left ventricular (LV) function.

Objectives: To assess the value of resting LV elastance (also known as force) with transthoracic echocardiography (TTE) to identify HFpEF phenotypes.

Methods: In a prospective, observational, multicenter study, 2380 HFpEF patients were recruited from July 2016 to May 2024.

View Article and Find Full Text PDF

Purpose: Recovery rate of rod photoreceptor sensitivity (S2 gradient) following a bleach is reduced in age-related macular degeneration (AMD) due to diminished delivery of retinol across a grossly altered Bruch's membrane. Since triterpenoid saponins are known to improve transport across Bruch's, we have assessed their possible use for reversing the visual deficits in AMD.

Design: Double-blind, placebo controlled randomised clinical trial.

View Article and Find Full Text PDF

Reliability of various Antimicrobial Susceptibility Testing Methods for Piperacillin/tazobactam in challenging Escherichia coli isolates.

J Glob Antimicrob Resist

January 2025

Department of Medical Microbiology and Infectious Diseases, Erasmus University Medical Center, Rotterdam, The Netherlands. Electronic address:

Piperacillin/tazobactam antimicrobial susceptibility testing (AST) against Enterobacterales can be challenging. The aim of this study was to assess the reproducibility of various automated (Vitek®2) and non-automated AST methods (broth microdilution (BMD), minimum inhibitory concentration (MIC) test strip, and disk diffusion) for piperacillin/tazobactam in 'challenging' E. coli isolates.

View Article and Find Full Text PDF

Over the last ten years, the US Centers for Disease Control and Prevention (CDC) has organized an annual influenza forecasting challenge with the motivation that accurate probabilistic forecasts could improve situational awareness and yield more effective public health actions. Starting with the 2021/22 influenza season, the forecasting targets for this challenge have been based on hospital admissions reported in the CDC's National Healthcare Safety Network (NHSN) surveillance system. Reporting of influenza hospital admissions through NHSN began within the last few years, and as such only a limited amount of historical data are available for this target signal.

View Article and Find Full Text PDF

CO-driven ion exchange for ammonium recovery from source-separated urine.

Water Res

January 2025

Georgia Tech Shenzhen Institute (GTSI), Tianjin University, Shenzhen 518067, China. Electronic address:

Nitrogen recovery from urine and CO utilization are both vital for achieving a circular economy and mitigating climate change. Divided engineering solutions have been proposed to address either problem, but there is still a lack of integrated technologies to simultaneously tackle the two tasks. We demonstrated CO-driven ion exchange for nitrogen recovery (CIXNR) from urine and evaluated the process in Malawi.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!