Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the observed inflow stenosis at the O-rings of the Ovation stent-graft and evaluate its hemodynamic and clinical impact.
Methods: The study involved 49 consecutive patients (48 men; mean age 71.2 ± 7.7 years) treated successfully with the Ovation abdominal aortic stent-graft between June 2011 and January 2014 at a single center. Cross-sectional area and radius measurements of the infrarenal aorta just proximal to the sealing mechanism, as well at the site of stenosis, were measured from 3D reconstructions of the 1-month postoperative computed tomographic angiograms. Based on Poiseuille's law, the predicted pressure drop was calculated for each patient based on the length of the stenosis. Invasive blood pressure measurements at 3 levels (proximal to the inflatable rings, halfway inside the stenosis, and distal to the stenosis) were obtained in 10 patients intraoperatively. Ankle-brachial index (ABI) values preoperatively were compared to those after the procedure for all patients to assess the clinical impact of this phenomenon.
Results: Median internal cross-sectional area at the site of the stenosis was significantly reduced compared to the area just proximal to the O-rings [57% reduction: 123 mm(2) (range 28-254) vs. 283 mm(2) (range 177-531), respectively; p<0.001]. The same was observed for the radius [6.5 mm (range 3-9) vs. 9.5 mm (range 7.5-13), respectively; p<0.001]. Based on the median 15 mm length of the stenosis (range 13-17) observed in the study population, a median pressure drop of 0.13 mmHg (range 0-0.25) along the stenosis was calculated. Invasive blood pressure measurements indicated a non-significant pressure change along the stenosis (e.g., 0.7 mmHg between the proximal level and halfway inside the stenosis). ABI remained practically unchanged postoperatively.
Conclusion: The advantages of the Ovation device's unique sealing mechanism come at the expense of a median area inflow stenosis of ∼ 60%. This stenosis does not cause a hemodynamically significant pressure drop. Future modification of the graft ring design may be needed in order to reduce this stenosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1583/14-4771MR.1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!