A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical evaluation of an expert system for arteriovenous fistula assessment. | LitMetric

Clinical evaluation of an expert system for arteriovenous fistula assessment.

Int J Artif Organs

1 Association Lorraine pour le Traitement de l'Insuffisance Rénale (ALTIR), Vandoeuvre-lès-Nancy - France.

Published: November 2014

The monitoring of ionic dialysance in hemodialysis allows early detection of arterio-venous fistula stenosis. One limitation to the practical use of ionic dialysance is that the analysis is very time consuming on a majority of normal cases.The purpose of the study is to evaluate the utility of an expert system reproducing a human analysis and allowing continuous monitoring of the ionic dialysance by helping the physician to focus his or her expertise on the abnormal cases.The method is based on a Bayesian model that analyzes the blood flow rate, the ionic dialysance, and the venous and arterial pressures measured on the extra corporeal circuit.The clinical evaluation was performed on 90 dialysis patients at the hospital dialysis center of Saint Brieux in France with a history of at least four consecutive months of validated recording. The retrospective automated analysis was evaluated in comparison to vascular access problems identified from invasive investigation or treatment. The sensitivity of the automated analysis is 92% with a specificity of 75%.As a conclusion we suggest that this expert system could be used in a continuous vascular access monitoring procedure consisting in a weekly review of the patient population at the dialysis center. The patients with the highest risk score need a further investigation of their historical data and their medical history in order to decide whether or not to perform an invasive intervention.

Download full-text PDF

Source
http://dx.doi.org/10.5301/ijao.5000364DOI Listing

Publication Analysis

Top Keywords

ionic dialysance
16
expert system
12
clinical evaluation
8
monitoring ionic
8
dialysis center
8
automated analysis
8
vascular access
8
evaluation expert
4
system arteriovenous
4
arteriovenous fistula
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!