Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Achieving accurate alignment in total knee arthroplasty (TKA) remains a concern. Patient-specific instrumentation (PSI) produced using preoperative 3D models was developed to offer surgeons a simplified, reliable, efficient and customised TKA procedure.
Methods: In this prospective study, 60 patients underwent TKA with conventional instrumentation and 71 patients were operated on using PSI. The primary endpoint was surgical time. Secondary endpoints included operating room (OR) time, the number of instrument trays used and postoperative radiographic limb alignment.
Results: Compared to conventional instrumentation, PSI significantly reduced total surgical time by 8.9 ± 3.3 min (p=0.038), OR time by 8.6 ± 4.2 min (p=0.043), and the number of instrument trays by six trays (p<0.001). Mechanical axis malalignment of the lower limb of >3° was observed in 13% of PSI patients versus 29% with conventional instrumentation (p=0.043). PSI predicted the size of the femoral and tibial components actually used in 85.9% and 78.9% of cases, respectively.
Conclusion: PSI improves alignment, surgical and OR time, reduces the number of instruments trays used compared to conventional instrumentation in patients undergoing TKA and results in fewer outliers in overall mechanical alignment in the coronal plane.
Level Of Evidence Ii: Prospective comparative therapeutic study.