Background: The potential for myocardial reconditioning and device explantation after long-term continuous-flow left ventricular assist device (LVAD) support presents an opportunity to delay or avoid transplantation in select patients.
Methods: Thirty of 657 patients with end-stage heart failure supported with continuous-flow LVADs were assessed for device explantation. Each patient underwent an individualized process of weaning focused on principles of ventricular unloading, gradual reconditioning, and transition to medical therapy.
Results: After varying reconditioning periods, 27 patients (16 men, 11 women; age, 39 ± 12 years) underwent LVAD explant, and 3 patients (2 men, 1 woman; age, 22 ± 6 years) were evaluated for explantation but could not be weaned. The duration of LVAD support was 533 ± 424 days (range, 42-1,937 days) for the explant cohort and 1,097 ± 424 days (range, 643-1,483) for the non-explant cohort. The LV end-diastolic dimension, LV ejection fraction, systolic pulmonary artery pressure, cardiac output, and cardiac index in the explant cohort were significantly improved at explantation (all, p < 0.05). Two late deaths occurred after LVAD explantation despite satisfactory native cardiac function, and 1 patient required resumption of LVAD support 2.7 years after device removal. The remaining explant patients remain in New York Heart Association classes I to II with medical management alone (mean survival post-explant, 1,172 ± 948 days). The 3 candidates who could not be weaned ultimately underwent transplantation.
Conclusions: The potential for recovery of native LV function after long-term continuous-flow LVAD support should encourage a more aggressive approach to ventricular reconditioning with the goal of device explantation and a return to medical management, particularly in young patients with dilated cardiomyopathy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4388806 | PMC |
http://dx.doi.org/10.1016/j.healun.2014.09.015 | DOI Listing |
Background: The use of mechanical circulatory support devices for high-risk percutaneous coronary intervention (PCI) has increased over the past decade despite limited data of benefit. We sought to examine the association between intravascular microaxial left ventricular assist device (LVAD) versus intra-aortic balloon pump use in patients without cardiogenic shock (CS) undergoing PCI.
Methods And Results: This retrospective study analyzed claims data from a large, insured population who underwent PCI without CS from April 1, 2016 to July 31, 2022.
ASAIO J
December 2024
Cleveland Clinic Florida, Heart, Vascular and Thoracic Institute, Advanced Heart Failure Program, Weston, Florida.
We investigated the association of preimplant left ventricular end-diastolic diameter (LVEDD) with outcomes after HeartMate 3 (HM3) left ventricular assist device (LVAD) implantation. Patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry who underwent HM3 implantation from August 2014 to February 2023 (n = 834) were analyzed according to preoperative LVEDD: less than or equal to 65 (n = 251), 65-80 (n = 441), and greater than or equal to 80 mm (n = 142). The mean age was 54.
View Article and Find Full Text PDFClin Transplant
January 2025
Department of Cardiovascular Surgery, Başkent University Faculty of Medicine, Ankara, Turkey.
Introduction: End-stage heart failure (ESHF) remains a significant challenge despite optimal treatment, with heart transplantation (HTx) being the gold standard of care. Mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs) are increasingly used for temporary or permanent treatment. Psychiatric comorbidities are common in patients with ESHF and may affect treatment outcomes, but the relationship between sociodemographic, clinical, and psychiatric characteristics remains unclear.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
March 2024
RWTH Aachen University, Aachen, Germany.
Introducing pulsatility in LVADs is known to reduce complications such as stagnation and thrombosis, but it is an ongoing topic of research on what the optimal form is. We present a framework consisting of parametrized full-order simulations, reduced-order models, and sensitivity analysis to systematically quantify the effects of parametrized pulsatility on washout. As a sample problem, we study the washout in an idealized 2D left ventricle and a parametrized sinusoidal LVAD flow rate.
View Article and Find Full Text PDFCirc Heart Fail
January 2025
Division of Cardiology, Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY. (S.R.P., M.A.V.).
Background: Patients with end-stage heart failure and low pulmonary capillary wedge pressure are referred to as cold and dry and represent an understudied minority in whom the benefit of left ventricular assist device (LVAD) therapy is unclear.
Methods: Adults receiving LVADs between 2006 and 2017 in the Interagency Registry for Mechanically Assisted Circulatory Support database were classified as cold and wet (pulmonary capillary wedge pressure >15 mm Hg) and cold and dry (pulmonary capillary wedge pressure ≤15 mm Hg) based on pre-LVAD hemodynamics obtained via right heart catheterization. The primary outcome was 1-year survival.