Introduction And Aim: Remote magnetic navigation has proved to be effective in the ablation of most supraventricular and ventricular arrhythmias. Initial studies reported worse results with this system compared to conventional ablation for atrial flutter. The aim of this study was to assess the acute and long-term success of atrial flutter ablation with remote magnetic navigation and to retrospectively compare the results obtained with an 8-mm tip catheter versus an irrigated catheter.
Methods: We studied 38 consecutive patients, mean age 61 ± 15 years, 28 male, who underwent ablation of typical atrial flutter with the Niobe II remote magnetic navigation system (Stereotaxis). Ablation was performed with an 8-mm tip catheter in 17 patients and with an irrigated-tip catheter in 21 patients. Acute success was defined as the presence of bidirectional isthmus block, and long-term success as absence of symptoms and atrial flutter during Holter monitoring.
Results: Bidirectional isthmus block was achieved in 37 patients (97%), and the success rate was similar in both groups. Total procedure time was not significantly different between the groups but fluoroscopy time was shorter in the irrigated tip group (13.4 ± 3.7 min vs. 6 ± 4.4 min; p<0.01). The number of applications and total radiofrequency time did not differ. There were no complications. During a follow-up of 32 ± 19 months there were two relapses, one in each group.
Conclusions: The Niobe II remote control system for ablation of typical atrial flutter is safe and effective in both the short and long term. The 8-mm and irrigated-tip catheters showed similar safety and efficacy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.repc.2014.05.003 | DOI Listing |
JACC Clin Electrophysiol
January 2025
Section of Cardiac Electrophysiology, Cardiovascular Medicine Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Background: Literature on the prevalence and management of atrial arrhythmias in patients with myotonic muscular dystrophy type 1 (MMD1) or myotonic muscular dystrophy type 2 (MMD2) is limited.
Objectives: This study sought to describe incidence, prevalence, and predictors of atrial fibrillation (AF) and atrial flutter (AFL) in a contemporary cohort of patients with myotonic muscular dystrophy (MMD).
Methods: Associations between patient factors and incident AF/AFL were analyzed in patients with MMD referred for routine electrophysiology evaluation between January 2013 and September 2023.
Digit Health
January 2025
Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Objective: Although the evaluation of left ventricular ejection fraction (LVEF) in patients with atrial fibrillation (AF) or atrial flutter (AFL) is crucial for appropriate medical management, the prediction of reduced LVEF (<50%) with AF/AFL electrocardiograms (ECGs) lacks evidence. This study aimed to investigate deep-learning approaches to predict reduced LVEF (<50%) in patients with AF/AFL ECGs and easily obtainable clinical information.
Methods: Patients with 12-lead ECGs of AF/AFL and echocardiography were divided into those with LVEF <50% and ≥50%.
J Cardiol Cases
October 2024
Department of Cardiology, Mater Dei Hospital, Msida, Malta.
Unlabelled: Pulmonary vein (PV) stenosis is a rare complication following PV isolation (PVI) for atrial fibrillation. Despite the benefit of early intervention, screening is not conducted, emphasizing the importance of maintaining a high index of suspicion. Standardized management approaches are unavailable for this serious complication.
View Article and Find Full Text PDFESC Heart Fail
January 2025
Mid-Atlantic Permanente Research Institute, Mid-Atlantic Permanente Medical Group, Washington, DC, USA.
Aims: Guideline-directed medical therapy (GDMT) is recommended for all patients with heart failure with reduced ejection fraction (HFrEF). Despite this, little data exist describing GDMT use in diverse, real-world populations including the use of vasodilators, prescribed primarily to Black populations. We sought, among a diverse population of HFrEF patients, to determine (1) GDMT use rates and target dosing by medication class and (2) predictors of GDMT use and target dosing by medication class.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2025
Department of Cardiology, Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, Zhejiang, China.
Background: Slow activation areas, characterized by decreased conduction velocities in the left atrium, are commonly observed in patients with persistent atrial fibrillation (PeAF). However, it remains unclear whether the ablation of slow activation areas combined with pulmonary vein isolation (PVI) improves clinical outcomes in these patients.
Methods: This single-center retrospective study included patients who underwent catheter ablation for PeAF.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!