Background: Whether the introduction of transcatheter aortic valve replacement (TAVR) has affected hospitals' surgical aortic valve replacement (SAVR) and overall aortic valve replacement (AVR) case volumes and outcomes in the United States is unknown.
Methods: We utilized data from The Society of Thoracic Surgeons (STS) adult cardiac surgery database and the STS/American College of Cardiology (ACC) transcatheter valve therapies registry to examine SAVR and TAVR procedures. Temporal trends in total case volume (SAVR plus TAVR), and observed and risk-adjusted in-hospital mortality rates were assessed among low-risk cases (STS predicted risk of operative mortality < 4%), intermediate-risk cases (4% to 8%), and high-risk cases (> 8%). A contemporary control was provided by non-TAVR centers.
Results: From 2008 to 2013, the total annual volume of AVR among 246 TAVR-performing hospitals increased from 19,578 to 33,004, with a 22% growth in SAVR volumes; non-TAVR hospital (n = 555) increases were more modest (16,563 to 19,134; 16% growth). Expanded volumes at TAVR hospitals included increased SAVR use in low- and intermediate-risk cases, and TAVR use in high-risk cases. In parallel, in-hospital mortality for all AVR procedures at TAVR sites declined from 3.4% to 2.9% (observed to expected [O:E] ratio 0.75 to 0.58, p < 0.001); the greatest declines were among intermediate- and high-risk SAVR patients. Owing to reduced SAVR mortality, TAVR centers experienced a significantly greater decline in O:E ratio for high-risk patient in-hospital mortality than non-TAVR centers (TAVR center O:E ratio, 0.81 to 0.61; non-TAVR center O:E ratio, 0.85 to 0.76; p < 0.001). After approval of TAVR for clinical use, a trend toward higher in-hospital mortality rates and O:E ratios for TAVR procedures was observed at new (but not at established) TAVR centers (O:E ratio, 0.41 to 0.67; p = 0.08).
Conclusions: Since the introduction of TAVR, the total volume of AVR procedures, including higher overall use of SAVR, at TAVR sites has significantly increased in the United States. Overall, in-hospital survival of patients undergoing treatment for aortic valve stenosis continues to improve.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.athoracsur.2014.07.051 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Graduate School of Public Health, St Luke's International University, Tokyo, Japan.
Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).
Methods: This study was a single-center retrospective cohort study.
Mol Diagn Ther
January 2025
Department of Medicine and Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, 4288A-1151 Richmond Street North, London, ON, N6A 5B7, Canada.
Clinical endpoints caused by hyperlipoproteinemia include atherosclerotic cardiovascular disease and acute pancreatitis. Emerging lipid-lowering therapies targeting proprotein convertase subtilisin/kexin 9 (PCSK9), lipoprotein(a), apolipoprotein C-III, and angiopoietin-like protein 3 represent promising advances in the management of patients with hyperlipoproteinemia. These therapies offer novel approaches for lowering pathogenic lipid and lipoprotein species, particularly in patients with serious perturbations who are not adequately controlled with conventional treatments or who are unable to tolerate them.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!