A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implant failure after biodegradable screw fixation in osteochondritis dissecans of the knee in skeletally immature patients. | LitMetric

Implant failure after biodegradable screw fixation in osteochondritis dissecans of the knee in skeletally immature patients.

Arthroscopy

Paediatric Orthopaedic Department, University Children's Hospital Basle (UKBB), Basel, Switzerland; Department of Orthopedic Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, U.S.A.

Published: March 2015

Purpose: The primary purpose of this study was to retrospectively assess the incidence of bioabsorbable screw failure in skeletally immature patients treated for osteochondritis dissecans (OCD) of the knee. The second purpose was to assess implant degradation, focusing on differential breakdown of the intraosseous and extraosseous parts of the screw on magnetic resonance imaging (MRI).

Methods: In this retrospective study, 24 patients (30 knees) with MRI-confirmed OCD were treated with a total of 61 biodegradable screws and followed up for a minimum of 2 years or until the onset of new symptoms. MRI scans were performed every 6 months to assess differences in signal intensity between the head and body of the screw. The angle between the surface of the head and the body of the screw was measured, with an angle greater than 90° interpreted as indicating a broken screw (i.e., failed implant).

Results: Seven screws (all 2.7 mm, 11.5% of all screws) in 5 patients were considered broken screws. The implant failed completely in an additional 4 patients with breakage of 7 of 9 screws; 3 patients were considered late failures, occurring after more than 6 months. Altogether, 14 of a total of 61 screws (23%) were broken.

Conclusions: Screw breakage is a surprisingly frequent cause of failure in resorbable OCD fixation in skeletally immature patients. MRI data showed differential decomposition of the screw within and outside of bone as a possible cause.

Level Of Evidence: Level IV, therapeutic case series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2014.08.032DOI Listing

Publication Analysis

Top Keywords

skeletally immature
12
immature patients
12
screw
8
osteochondritis dissecans
8
head body
8
body screw
8
screws patients
8
patients considered
8
patients
7
screws
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!