Objective: Persistent retrograde false lumen perfusion is a common mode of failure after thoracic endovascular aortic repair (TEVAR) for chronic dissection. Objectives were to describe a novel endovascular approach for false lumen occlusion and assess outcomes.
Methods: From 2009 to 2013, 21 patients (mean age, 64 ± 11 years) with chronic thoracoabdominal dissection underwent adjunctive false lumen embolization using covered stent devices for persistent retrograde perfusion. Eight patients had type B dissection, 13 had residual dissection after prior type A repair, and all were deemed high risk for open operation. False lumen embolization in 17 patients was an adjunct at the initial TEVAR or extension, including two as elephant trunk completion. In the other four, this was done as an isolated procedure, and three had previously undergone TEVAR sparing the celiac artery. Covered stent devices included iliac plugs in 18, nitinol embolization plugs in two, and occluded stent graft in one. More than one device was used in 15 patients.
Results: There was one hospital death due to left subclavian artery aneurysm rupture but no patient had stroke, paraplegia, myocardial infarction, or renal failure. Mean follow-up was 25 ± 19 months. During surveillance computed tomography imaging, false lumen thrombosis was noted in all patients, but four required further embolization because the thrombosis was incomplete. Mean maximum aortic diameter decreased from 64 ± 14 to 59 ± 15 mm. There was one late death from intracranial hemorrhage and no aortic ruptures.
Conclusions: Adjunctive false lumen embolization with a covered stent device promotes thrombosis and remodeling after stent grafting the true lumen for chronic dissection. Further study of this strategy is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2014.08.094 | DOI Listing |
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
June 2024
Department of Cardiovascular Surgery, Fukushima Medical University, Fukushima, Japan.
Background: There is limited experience and knowledge of the use of the fenestrated frozen elephant trunk (FET) technique in acute type A aortic dissection (ATAAD). This study's aims were to assess the clinical outcomes of the fenestrated FET technique for ATAAD and to identify its best practices and pitfalls.
Methods: This study included 101 patients who underwent emergency surgical aortic repair for ATAAD at our hospital between October 2018 and April 2023.
Vascular
January 2025
Division of Vascular Surgery, Medical University of South Carolina, Charleston, SC, USA.
Objectives: Mal-deployment of the thoracic endovascular aortic repair (TEVAR) stent graft during a frozen elephant trunk (FET) procedure for an acute type A aortic dissection (ATAAD) leads to devastating complications. We report a hemiarch replacement with TEVAR stent graft covering the aortic arch vessels salvaged through an endovascular approach.
Methods: A 69-year-old man with ATAAD in 2018, status post-hemiarch repair with TEVAR, presented in 2023 with progressive dizziness/syncope and lower extremity hypertension with inability to tolerate anti-hypertensives.
Cureus
December 2024
Department of Neurosurgery, Hirosaki University Graduate School of Medicine, Hirosaki, JPN.
Tandem occlusion due to acute cervical carotid artery dissection should be promptly treated with thrombectomy for reperfusion. If the cervical lesion has reached severe stenosis or complete occlusion, balloon angioplasty and, in certain cases, carotid artery stenting should be performed before thrombectomy for the intracranial lesion. Angioplasty or stent placement is performed in the true lumen, but securing the placement is challenging when the true lumen cannot be determined.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Translational Imaging Centre, Houston Methodist Research Institute, Houston, TX 77030, USA.
Objective: To develop an unsupervised artificial intelligence algorithm for identifying and quantifying the presence of false lumen thrombosis (FL) after Frozen Elephant Trunk (FET) operation in computed tomography angiographic (CTA) images in an interdisciplinary approach.
Methods: CTA datasets were retrospectively collected from eight patients after FET operation for aortic dissection from a single center. Of those, five patients had a residual aortic dissection with partial false lumen thrombosis, and three patients had no false lumen or thrombosis.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!