Objective: Polyaxial screw-rod fixation of C1-C2 is a relatively new technique to treat atlantoaxial instability, and there have been few reports in the literature outlining all possible complications. The purpose of this case report is to present the occurrence and management of occipital bone erosion induced by the protruded rostral part of a posterior atlantoaxial screw-rod construct causing headache.

Clinical Features: A 70-year-old Asian man with rheumatoid arthritis initially presented to our institution with atlantoaxial instability causing progressive quadraparesis and neck pain.

Intervention And Outcome: Posterior atlantoaxial instrumented fixation using C1 lateral mass screws in conjunction with C2 pedicle screws was performed to stabilize these segments. Postoperatively, the patient regained the ability to independently walk and had no radiographic evidence of instrumentation hardware failure and excellent sagittal alignment. However, despite a well-stabilized fusion, the patient began to complain of headache during neck extension. Follow-up imaging studies revealed left occipital bone erosion induced by a protruded titanium rod fixed with setscrews. During revision surgery, the rod protrusion was modified and the headaches diminished.

Conclusion: This case demonstrates that occipital bone erosion after posterior atlantoaxial fixation causing headache may occur. The principal cause of bone erosion in this case was rod protrusion. Although posterior atlantoaxial fixation using the screw-rod system was selected to manage atlantoaxial instability because it has less complications than other procedures, surgeons should pay attention that the length of the rod protrusion should not exceed 2 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4241472PMC
http://dx.doi.org/10.1016/j.jcm.2014.08.004DOI Listing

Publication Analysis

Top Keywords

bone erosion
20
atlantoaxial instability
16
occipital bone
16
posterior atlantoaxial
16
erosion induced
12
induced protruded
12
rod protrusion
12
atlantoaxial
8
titanium rod
8
case report
8

Similar Publications

Background: Among several skin fillers developed in recent decades, hyaluronic acid (HA) is a widely used filler for face contouring and is generally believed to be safe, long-lasting, not immunogenic, and cost-effective. However, early and delayed complications can also occur following HA filler injection. Unfortunately, there have been reports of HA-related bone erosion in the chin area without clear scientific data regarding its existence and incidence.

View Article and Find Full Text PDF

Challenges in the Management of a Calvarial Defect in an NF1-Patient.

Diseases

December 2024

The Leo M. Davidoff Department of Neurological Surgery, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, NY 10467, USA.

Background: Calvarial defects in NF1 are rare and lack standardized management guidelines. This study seeks to shed light on calvarial defects in NF1 patients with extensive skull erosion.

Methods: This case report focuses on clinical and radiological presentations and surgical interventions during six years of follow-up, comparing the results with those in the literature.

View Article and Find Full Text PDF

Background: Orbital rhabdomyosarcoma (RMS) is often limited to the orbital cavity and has a favorable prognosis. In some cases, the tumor can erode the orbital bone and behave as a parameningeal RMS (PM-RMS); thus, it is treated more intensively. However, the current protocols do not provide any guidance on how to consider different grades of bone erosion (BE) that can vary widely, hampering a uniform classification and the subsequent treatment assignment.

View Article and Find Full Text PDF

In order to delay the progression of Rheumatoid Arthritis (RA) in patients, and to prevent further teratogenesis and irreversible bone erosion through drug intervention in the early stages of inflammation, this experiment used the mRNA encoding heat shock protein 10 (HSP10) (H-mRNA) as the main therapeutic drug and used Microfluidics technology to prepare lipid nanoparticles (LNP) (H-mRNA LNPs) containing H-mRNA, and the surface of H-mRNA-LNPs was modified using heparin particals to obtain the final formulation H-mRNA-LNPs @ heparin/ Protamine. Through the sequence modification and effect evaluation of H-mRNA, we explored the formulation screening, physical characterization, cytotoxicity in vitro, distribution in vivo, pharmacodynamics in vivo, and safety in vivo of the prepared lipid nanoparticles, which proved that this nano-preparation had good anti Rheumatoid Arthritis effects, and conducted a preliminary exploration for the application of nucleic acid drugs in the treatment of diseases outside of tumors. This research would provide new ideas for the treatment of RA.

View Article and Find Full Text PDF

The aim of the present study was to explore the role of ovarian cancer G protein-coupled receptor 1 (OGR1) in osteoclast differentiation and activity induced by extracellular acid. The impact of extracellular acidification on osteoclasts was investigated. Briefly, osteoclasts were generated from RAW 264.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!