A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 μm wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4891875DOI Listing

Publication Analysis

Top Keywords

electron beam
12
extreme ultraviolet
8
beam ion
8
extended-range grazing-incidence
4
grazing-incidence spectrometer
4
spectrometer high-resolution
4
high-resolution extreme
4
ultraviolet measurements
4
measurements electron
4
ion trap
4

Similar Publications

Laser surface alloying of Fe, Si, and C on aluminium is demonstrated using a Q-switched Nd:YAG laser as the source of energy. The fundamental wavelength of the laser beam was 1064 nm with an output energy of 100 mJ and a pulse duration of 10 ns. The exposure was conducted in repetitive mode with a frequency rate of 1 Hz.

View Article and Find Full Text PDF

The content of flavor compounds in wine is limited by factors such as climate warming and the resistance of cell walls to maceration. This study used X-rays (ionizing radiation) and electron beams (particle radiation) at 0.5, 2, and 7 kGy for grape pre-treatment before winemaking.

View Article and Find Full Text PDF

An applied noise model for scintillation-based CCD detectors in transmission electron microscopy.

Sci Rep

January 2025

Nanopatterning-Nanoanalysis-Photonic Materials Group, Department of Physics, Paderborn University, Warburgerstr. 100, 33098, Paderborn, Germany.

Measurements in general are limited in accuracy by the presence of noise. This also holds true for highly sophisticated scintillation-based CCD cameras, as they are used in medical applications, astronomy or transmission electron microscopy. Further, signals measured with pixelated detectors are convolved with the inherent detector point spread function.

View Article and Find Full Text PDF

Precise measurements of fundamental decay data such as energies and transition probabilities of radioactive isotopes are important for the development of corresponding nuclear modelling, activity determination and various applications in science and technology. The EMPIR project PrimA-LTD -"Towards new Primary Activity standardisation methods based on Low-Temperature Detectors" - aims to measure the electron-capture decay of Fe very precisely using Metallic Microcalorimeters (MMCs) with outstandingly high energy resolution. Using a high-statistics measurement, electron-capture probabilities shall be precisely determined and higher-order effects such as electron shake-up and shake-off shall be examined with unprecedented precision.

View Article and Find Full Text PDF

A simple cavity-enhanced laser-based heater for reflective samples.

Rev Sci Instrum

January 2025

Institute for Physical Chemistry, University of Göttingen, 37077 Göttingen, Germany.

Surface science instruments require excellent vacuum to ensure surface cleanliness; they also require control of sample temperature, both to clean the surface of contaminants and to control reaction rates at the surface, for example, for molecular beam epitaxy and studies of heterogeneous catalysis. Standard approaches to sample heating within high vacuum chambers involve passing current through filaments of refractory metals, which then heat the sample by convective, radiative, or electron bombardment induced heat transfer. Such hot filament methods lead to outgassing of molecules from neighboring materials that are inadvertently heated; they also produce electrons and ions that may interfere with other aspects of the surface science experiment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!