A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model. | LitMetric

Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

Radiology

From the Departments of Radiology (T.A.P., C.L.B., M.G.L., L.A.S., B.J.W., F.T.L.), Biomedical Engineering (C.L.B.), and Medical Physics (C.L.B.), University of Wisconsin-Madison, E3/366 Clinical Science Center, 600 Highland Ave, Madison, WI 53792.

Published: April 2015

Purpose: To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model.

Materials And Methods: The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons.

Results: The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P < .0001). Conspicuity of ischemic segments was significantly greater on dual-energy iodine material-density and 51-keV CT images than on 120-kVp CT images (mean contrast-to-noise ratios, 4.9, 4.3, and 2.1, respectively; P < .0001). Although attenuation differences on dual-energy 65- and 70-keV CT images were not significantly different from those on 120-kVp images (55.0 HU, 45.8 HU, and 47.6 HU, respectively; 65 keV vs 120 kVp, P = .15; 70 keV vs 120 kVp, P = .46), the contrast-to-noise ratio was greater for the 65- and 70-keV images than for the 120-kVp images (4.4, 4.1, and 2.1 respectively; P < .0005).

Conclusion: Dual-energy CT significantly improved the conspicuity of the ischemic bowel compared with conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.14140875DOI Listing

Publication Analysis

Top Keywords

120-kvp images
20
120 kvp
12
ischemic perfused
12
perfused segments
12
images 120-kvp
12
images
10
dual-energy
9
small-bowel ischemia
8
compared conventional
8
ischemic bowel
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!