Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T.

Radiol Med

Department of Medical and Biological Sciences, Institute of Diagnostic Radiology, University of Udine, Via Colugna n. 50, 33100, Udine, Italy,

Published: June 2015

Purpose: This study was done to evaluate test-retest reliability of liver diffusion tensor imaging (LDTI).

Materials And Methods: Ten healthy volunteers (median age 23 years) underwent two LDTI scans on a 3.0 T magnet during two imaging sessions separated by 2 weeks (session-1/-2, respectively). Fifteen gradient directions and b values of 0-1,000 s/mm(2) were used. Two radiologists in consensus assessed liver apparent diffusion coefficient (ADC) and fraction of anisotropy (FA) values on ADC and FA maps at four reference levels, namely: right upper level (RUL), right lower level (RLL), left upper level (LUL) and left lower level (LLL). We then assessed (a) whether ADC and FA values overlapped when measured on different levels within the same imaging session or between different imaging sessions; (b) the degree of variability on an intra-session and inter-session basis, respectively, using the coefficient of variation (CV).

Results: In sessions 1 and 2, the ADC/FA values were significantly larger in the left liver lobe (LUL/LLL) compared to right liver lobe (RUL/RLL) (p < 0.05/6). Intra-session CVs were 9.51 % (session 1) and 9.73 % (session 2) for ADC, and 12.93 % (session 1) and 11.82 % (session 2) for FA, respectively. When comparing RUL, RLL, LUL and LLL on an inter-session basis, CVs were 6.52, 8.20, 6.52 and 11.06 % for ADC, and 15.42, 15.80, 15.42 and 6.80 % for FA, respectively.

Conclusion: LDTI provides consistent and repeatable measurements. However, since larger left lobe ADC/FA values can be attributed to artefacts, right lobe values should be considered the most reliable measurements of water diffusivity within the liver.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-014-0479-8DOI Listing

Publication Analysis

Top Keywords

test-retest reliability
8
diffusion tensor
8
tensor imaging
8
imaging sessions
8
upper level
8
lower level
8
liver lobe
8
imaging
5
liver
5
reliability diffusion
4

Similar Publications

A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.

View Article and Find Full Text PDF

Simultaneous Determination of Vitamins A and E and Their Generated Metabolites in Human Serum by LC-MS/MS.

Biomed Chromatogr

January 2025

Beijing Harmony Health Medical Diagnostics Co., Ltd., Beijing, China.

In the context of personalized and precision medicine, simultaneous monitoring of different forms of vitamins A and E and their metabolites could help us better understand the status of vitamins A and E in the body. The aim of this study was to establish a method for simultaneous determination of 13 kinds of vitamins A and E and their metabolites in human serum. Serum samples were directly detected by LC-MS/MS after deproteinization.

View Article and Find Full Text PDF

In the current study, the analytical sensitivity, analytical specificity, reproducibility, anti-interferences ability, and clinical performance of the QIAstat-Dx Gastrointestinal Panel (GIP) system were evaluated using pooled stool samples. Results showed that the pooled sample test detected the selected ten targets exclusively, with no cross reaction with any other targets of common enteropathogens. The analytical sensitivity of the pooled sample test on QIAstat-Dx GIP system was 10 CFU/ml for Shigella spp.

View Article and Find Full Text PDF

Aim: To translate the 9-item Confidence in Dementia (CODE) scale into Chinese (Confidence in Dementia-Chinese, CODE-C) and evaluate its psychometric properties among clinical nurses.

Background: With the rapidly ageing population, an increasing number of patients with dementia will be cared for in hospitals. Clinical nurses' confidence in dementia care is crucial to provide quality care.

View Article and Find Full Text PDF

Purpose: To linguistically and cross-culturally translate Hip Disability and Osteoarthritis Outcome Score into Urdu language (HOOS-U), and test its psychometric properties among patients with hip pain.

Materials And Methods: Translation and cross-cultural adaptation of English version of HOOS were carried out following international guidelines. Psychometric testing included reliability (internal consistency and test-retest reliability), validity (content and construct validity) and responsiveness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!