A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system. | LitMetric

Object: Fractures of C-1 and C-2 are complex and surgical management may be difficult and challenging due to the anatomical relationship sbetween the vertebrae and neurovascular structures. The aim of this study was to evaluate the role, reliability, and accuracy of cervical fixation using the O-arm intraoperative 3D image-based navigation system.

Methods: The authors evaluated patients who underwent a navigation system-based surgery for stabilization of a fracture of C-1 and/or C-2 from August 2011 to August 2013. All of the fixation screws were intraoperatively checked and their position was graded.

Results: The patient population comprised 17 patients whose median age was 47.6 years. The surgical procedures were as follows: anterior dens screw fixation in 2 cases, transarticular fixation of C-1 and C-2 in 1 case, fixation using the Harms technique in 12 cases, and occipitocervical fixation in 2 cases. A total of 67 screws were placed. The control intraoperative CT scan revealed 62 screws (92.6%) correctly placed, 4 (5.9%) with a minor cortical violation (<2 mm), and only 1 screw (1.5%) that was judged to be incorrectly placed and that was immediately corrected. No vascular injury of the vertebral artery was observed either during exposition or during screw placement. No implant failure was observed.

Conclusions: The use of a navigation system based on an intraoperative CT allows a real-time visualization of the vertebrae, reducing the risks of screw misplacement and consequent complications.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2014.10.SPINE14122DOI Listing

Publication Analysis

Top Keywords

c-1 c-2
8
fixation cases
8
fixation
6
management c1-2
4
c1-2 traumatic
4
traumatic fractures
4
fractures intraoperative
4
intraoperative imaging-based
4
imaging-based navigation
4
navigation system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!