Changes in platelet indices in children with bicuspid aortic valve.

Pediatr Cardiol

Department of Paediatric Hematology, Goztepe Training Hospital, Medeniyet University, Istanbul, Turkey,

Published: March 2015

Mean platelet volume (MPV) and platelet distribution width (PDW) can help diagnose cardiovascular pathologies. In this study, we aimed to demonstrate the changes in platelet (PLT) indices in children diagnosed with bicuspid aortic valve (BAV) with mild stenosis and without stenosis to compare patients with mild stenosis with those without stenosis. A total of 73 children diagnosed with BAV (30 patients with mild stenosis and 43 without stenosis) with a mean age 9.73 ± 5.01 years and a control group were included in the study. Mean MPV value was significantly lower in the control group compared with patients with BAV with mild stenosis and patients without stenosis (p = 0.001, and p < 0.01, respectively). MPV was significantly greater in patients with mild stenosis than in patients without stenosis (p = 0.049 and p < 0.05, respectively). Patients with mild stenosis had a significantly greater mean PDW value compared with patients without stenosis and the control group (p = 0.024 and p < 0.05, respectively). There was no significant difference between patients without stenosis and the control group with respect to mean PDW value (p > 0.05). In conclusion, the results of this study demonsrate that children with BAV either with or without stenosis have increased MPV; the ones with mild stenosis have even greater values than the ones without stenosis. It emphasizes the risk of thrombosis in children with BAV.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-014-1062-8DOI Listing

Publication Analysis

Top Keywords

mild stenosis
16
stenosis stenosis
12
changes platelet
8
indices children
8
bicuspid aortic
8
aortic valve
8
children diagnosed
8
bav mild
8
stenosis
8
patients mild
8

Similar Publications

Introduction: Ultrasonography is increasingly used to diagnose the carpal tunnel syndrome (CTS). Most frequently, the enlargement of the nerve cross-sectional area (CSA) at the tunnel inlet serves to confirm the diagnosis. Recent research has shown that the nerve diameter is decreased within the tunnel, when measured at the level of pisiforme or capitatum.

View Article and Find Full Text PDF

Objectives: This study aims to develop and validate nomograms that utilize morphological and radiomics features derived from computed tomography enterography (CTE) to evaluate inflammatory activity in patients with ileocolonic Crohn's disease (CD).

Methods: A total of 54 CD patients (237 bowel segments) with clinically confirmed CD were retrospectively analyzed. The Simple Endoscopic Score for Crohn's Disease (SES-CD) was used as a reference standard to quantify the degree of mucosal inflammation and assess disease severity.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Purpose: To investigate the presence and/or severity of cervicothoracic foraminal stenosis between the C7 and T3 segments could account for Horner syndrome, otherwise deemed to be idiopathic in nature.

Methods: This study was an IRB-approved, retrospective study that included 28 patients [mean ± standard deviation (age: 54.5 ± 18.

View Article and Find Full Text PDF

Mitral and aortic annular calcification is an age-related degenerative process that can result in severe mitral and/or aortic stenosis and/or regurgitation. Annular calcification not only increases the surgical complexity but also increases the risk of complications. In this case report, we present the innovative use of the Sonopet ultrasonic surgical aspirator for aortic and mitral annular decalcification in a patient with hypertrophic obstructive cardiomyopathy, mild aortic stenosis and moderate mitral regurgitation in the presence of mitral annular calcification (MAC) and aorto-mitral curtain calcification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!