Femtosecond laser cutting of endothelial grafts: comparison of endothelial and epithelial applanation.

Cornea

*Corneal Graft Biology, Engineering and Imaging laboratory, EA2521, SFR143, Faculty of Medicine, University Jean Monnet, Saint-Etienne, France; †Department of Ophthalmology, University Hospital, Besançon, France; ‡Department of Ophthalmology, University Hospital, Saint-Etienne, France; §Manutech Ultrafast Surfacing Design, Pole Optique Rhône-Alpes, Saint-Etienne, France; ¶Department of Pathology, University Hospital, Saint-Etienne, France; and ‖Institut Universitaire de France, Boulevard Saint-Michel, Paris, France.

Published: February 2015

Purpose: Stromal surface quality of endothelial lamellae cut for endothelial keratoplasty with a femtosecond laser (FSL) with epithelial applanation remains disappointing. Applanation of the endothelial side of the cornea, mounted inverted on an artificial chamber, has therefore been proposed to improve cut quality. We compared lamellar quality after FSL cutting using epithelial versus endothelial applanation.

Method: Lamellae were cut with an FSL from organ-cultured corneas. After randomization, 7 were cut with epithelial applanation and 7 with endothelial applanation. Lamellae of 50-, 75-, and 100-μm thickness were targeted. Thickness was measured by optical coherence tomography before and immediately after cutting. Viable endothelial cell density was quantified immediately after cutting using triple labeling with Hoechst/ethidium/calcein-AM coupled with image analysis with ImageJ. The stromal surface was evaluated by 9 masked observers using semiquantitative scoring of scanning electronic microscopy images. Histology of 2 samples was also analyzed before lamellar detachment.

Results: Precision (difference in target/actual thickness) and thickness regularity [coefficient of variation (CV) of 10 measurements] were significantly better with endothelial applanation (precision: 18 μm; range, 10-30; CV: 11%; range, 8-12) than with epithelial applanation (precision: 84 μm; range, 54-107; P = 0.002; CV: 24%; range, 13-47; P = 0.001). Endothelial applanation provided thinner lamellae. However, viable endothelial cell density was significantly lower after endothelial applanation (1183 cells/mm2; range, 787-1725 versus 1688 cells/mm2; range, 1288-2025; P = 0.018).

Conclusions: FSL cutting of endothelial lamellae using endothelial applanation provides thinner more regular grafts with more predictable thickness than with conventional epithelial applanation but strongly reduces the pool of viable endothelial cells.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000000314DOI Listing

Publication Analysis

Top Keywords

epithelial applanation
20
endothelial applanation
20
endothelial
15
viable endothelial
12
applanation
11
femtosecond laser
8
cutting endothelial
8
stromal surface
8
endothelial lamellae
8
lamellae cut
8

Similar Publications

Pressure-Induced Stromal Keratopathy after Surface Ablation Surgery.

Case Rep Ophthalmol

July 2024

Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil.

Introduction: The purpose of this clinical report was to describe an unprecedented case of bilateral pressure-induced stromal keratopathy (PISK) following corneal photorefractive keratectomy, associated with presumed herpetic keratitis, and to present tomographic and biomechanical findings before and after appropriate treatment.

Case Presentation: A 33-year-old male patient was referred to our clinic with suspected delayed corneal epithelial healing 3 weeks after an uncomplicated PRK. A central layer of corneal opacity with a presumed fluid-filled interface area was observed upon slit lamp biomicroscopy.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of latanoprost, bimatoprost, and travoprost eye drops and their preservatives on each corneal layer thickness in patients with primary open-angle glaucoma (POAG).

Methods: We retrospectively analyzed 79 eyes of 79 patients with POAG who were receiving prostaglandin therapy. Patients were divided into three subgroups according to monotherapy with latanoprost, bimatoprost, and travoprost during a mean of 43.

View Article and Find Full Text PDF

[Femtosecond laser-assisted minimally invasive lamellar keratoplasty for advanced keratoconus].

Zhonghua Yan Ke Za Zhi

April 2023

Eye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Jinan 250021, China.

To evaluate the initial safety and efficacy of femtosecond laser-assisted minimally invasive lamellar keratoplasty (FL-MILK) for advanced keratoconus. It was a case series study. Patients with advanced keratoconus who underwent FL-MILK between August 2017 and April 2020 at Shandong Eye Hospital were prospectively included.

View Article and Find Full Text PDF

Background/aims: To compare the ocular biomechanical properties of inactive Grave's orbitopathy (GO) patients and healthy subjects and to evaluate the influence of severity and phenotype of GO on these parameters.

Methods: This was a cross-sectional study. All included inactive GO patients and healthy controls underwent complete ocular examination, including Goldman applanation tonometry (GAT), corneal biomechanical analysis using Ocular Response Analyser (ORA), and corneal epithelial thickness analysis using Optovue.

View Article and Find Full Text PDF

Purpose: This study aimed to determine the relationship between corneal cellular structures and biomechanical deformation parameters in keratoconic (KC) and healthy eyes.

Methods: In this prospective comparative study, 29 eyes of 29 KC patients were age- and gender-matched with 28 eyes of 28 healthy individuals using frequency matching. Corneal parameters examined included the density of basal epithelial cells, anterior keratocytes, posterior keratocytes and endothelial cells as assessed by in vivo corneal confocal microscopy (HRT III-RCM, Heidelberg Engineering, www.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!