Greater sensory stimulation in advertising has been postulated to facilitate attention and persuasion. For this reason, video ads promoting health behaviors are often designed to be high in "message sensation value" (MSV), a standardized measure of sensory intensity of the audiovisual and content features of an ad. However, our previous functional Magnetic Resonance Imaging (fMRI) study showed that low MSV ads were better remembered and produced more prefrontal and temporal and less occipital cortex activation, suggesting that high MSV may divert cognitive resources from processing ad content. The present study aimed to determine whether these findings from anti-smoking ads generalize to other public health topics, such as safe sex. Thirty-nine healthy adults viewed high- and low MSV ads promoting safer sex through condom use, during an fMRI session. Recognition memory of the ads was tested immediately and 3 weeks after the session. We found that low MSV condom ads were better remembered than the high MSV ads at both time points and replicated the fMRI patterns previously reported for the anti-smoking ads. Occipital and superior temporal activation was negatively related to the attitudes favoring condom use (see Condom Attitudes Scale, Methods and Materials section). Psychophysiological interaction (PPI) analysis of the relation between occipital and fronto-temporal (middle temporal and inferior frontal gyri) cortices revealed weaker negative interactions between occipital and fronto-temporal cortices during viewing of the low MSV that high MSV ads. These findings confirm that the low MSV video health messages are better remembered than the high MSV messages and that this effect generalizes across public health domains. The greater engagement of the prefrontal and fronto-temporal cortices by low MSV ads and the greater occipital activation by high MSV ads suggest that that the "attention-grabbing" high MSV format could impede the learning and retention of public health messages.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237381 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0113256 | PLOS |
Health Phys
January 2025
Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, M5B 2K3.
This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.
View Article and Find Full Text PDFAm J Emerg Med
December 2024
Department of Emergency Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA. Electronic address:
Background: Recent studies have validated the efficacy of point-of-care ultrasound (POCUS) as an alternative diagnostic imaging approach to computed tomography (CT) for patients with suspected acute diverticulitis. This study aimed to quantify the national impact of this approach in cost savings, ED length-of-stay (LOS), and radiation risk mitigation using a POCUS-first approach for acute diverticulitis in the emergency department (ED).
Methods: Using published data, we constructed a Monte Carlo simulation model to compare two POCUS-first strategies (nonselective and selective approaches) for evaluating patients with suspected acute diverticulitis in the ED.
J Crohns Colitis
January 2025
Translational Research in Gastrointestinal Disorders (TARGID), Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium and Department of Gastroenterology and Hepatology, University Hospitals Leuven, Belgium.
Background And Aims: Radiological imaging is crucial for diagnosing and monitoring patients with inflammatory bowel diseases (IBD). With increasing awareness of radiation risks, imaging doses should be 'as low as reasonably achievable', with a risk level that one should try to stay underneath 75 mSv. However, real-world data on cumulative exposure are limited.
View Article and Find Full Text PDFEnviron Geochem Health
January 2025
Nuclear Technology Research and Development Center, Thailand Institute of Nuclear Technology, Nakhon Nayok, 26120, Thailand.
The present study aimed to investigate the hydrogeochemical patterns and contamination of the radiogeology, especially radon activity, related to geothermal aquifer properties and to perform a risk assessment of annual effective doses covering all hydrothermal spring attractions in Southern Thailand. Radon is an established lung carcinogen; especially longer term exposure to radioactive radon through inhalation could be a cause of lung cancer risk. Altogether 22 hydrothermal spring samples were collected from the six hydrothermal provinces in Southern Thailand in early November of 2023.
View Article and Find Full Text PDFEmerg Med Australas
February 2025
Royal Prince Alfred Hospital, Camperdown, New South Wales, Australia.
Objective: To compare the frequency of clinically significant missed injuries in clinically stable trauma patients undergoing initial whole-body computed tomography (WBCT) versus selective imaging. Secondary objectives include comparisons of radiation exposure, incidental findings, ED length of stay (LOS), hospital LOS and mortality.
Methods: We performed a retrospective cohort study of trauma activations at a tertiary trauma centre in patients with normal vital signs from 1st January 2022 to 31st December 2022.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!