Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation.

Interact Cardiovasc Thorac Surg

Department of Cardiac Surgery, Hospital Meixoeiro, Complejo Hospitalario Universitario de Vigo, Vigo, Spain.

Published: February 2015

Bioprosthetic valves are used in aortic valve replacement to avoid lifelong anticoagulation. Bovine pericardial valves have excellent haemodynamics and equivalent freedom from reoperation compared with a porcine bioprosthesis [ 1]. However, early failure (parastent post-cusp tear) can take place due to mechanical stress. We report an acute structural failure on a Trifecta pericardial valve (St Jude Medical, Inc.) explanted after 34 months from a 71-year old woman.

Download full-text PDF

Source
http://dx.doi.org/10.1093/icvts/ivu384DOI Listing

Publication Analysis

Top Keywords

leaflet tear
4
tear trifecta
4
trifecta aortic
4
aortic bioprosthesis
4
bioprosthesis months
4
months implantation
4
implantation bioprosthetic
4
bioprosthetic valves
4
valves aortic
4
aortic valve
4

Similar Publications

Background: There are several high-risk treatment options for valve failure of a biological full root replacement. When tailoring the best treatment option for the patient, implantation of a rapid deployment valve (RDV) should be considered.

Case Presentation: Six patients presented with aortic regurgitation in a full root Freestyle bioprosthesis.

View Article and Find Full Text PDF

Background: Acute mitral regurgitation due to papillary muscle rupture is a severe complication of acute myocardial infarction. Transcatheter edge-to-edge repair is emerging as an effective alternative to surgical treatment, with encouraging outcomes. Leaflet adverse events are rare and are associated with relapse of significant mitral regurgitation.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to streamline the process of 3D printing patient-specific mitral valves in soft materials, which is typically lengthy and complex.
  • Researchers developed a technique using transesophageal echocardiography data and various software tools, focusing on adjusting curing times, model thinness, and lattice structures during printing.
  • Results showed that realistic and flexible mitral valves could be printed in 1.5 to 4.5 hours, with optimal modifications leading to better functionality for simulation training purposes.
View Article and Find Full Text PDF

Rheumatic mitral stenosis is a common rheumatic heart diseases in sub-Saharan Afrleading to increased morbidity and mortality. Percutaneous mitral balloon valvuloplasty is the mainstay of less invasive therapy in those with moderate to severe valve stenosis, being symptomatic despite optimal medical therapy. Though generally save with experienced hand and setup, post procedural complications include development of mitral regurgitation, tear and thrombosis.

View Article and Find Full Text PDF
Article Synopsis
  • Managing horizontal cleavage tears in the medial meniscus is complex, with various nonoperative and surgical treatments available, each having its own pros and cons.
  • Existing repair methods have been successful but can lead to issues like recurrent cysts and reduced meniscal volume.
  • A new surgical technique using a strip of autologous quadriceps tendon, combined with an all-inside compression suture, is proposed as a solution for young patients, aiming to improve the healing process and address previous treatment limitations.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!