We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.22.025043DOI Listing

Publication Analysis

Top Keywords

laser frequency
8
yb+ ions
8
stabilized lasers
8
laser
6
coupled optical
4
optical resonance
4
resonance laser
4
laser locking
4
locking demonstrated
4
demonstrated simultaneous
4

Similar Publications

Ocular microtremor (OMT) is a fixational eye movement that cannot be seen with the naked eye but is always present, even when the eye appears motionless/still. The link between OMT and brain function provides a strong rationale for investigation as there lies potential for its use as a biomarker in populations with neurological impairments. OMT frequency is typically 70-80Hz in healthy adults and research suggests that this will be reduced in those with neurological disease such as Parkinson's Disease (PD).

View Article and Find Full Text PDF

Experimental demonstration of 8190-km long-haul semiconductor-laser chaos synchronization induced by digital optical communication signal.

Light Sci Appl

January 2025

Key Laboratory of Photonic Technology for Integrated Sensing and Communication, Ministry of Education of China, Guangdong University of Technology, Guangzhou, 510006, China.

Common-signal-induced synchronization of semiconductor lasers have promising applications in physical-layer secure transmission with high speed and compatibility with the current fiber communication. Here, we propose an ultra-long-distance laser synchronization scheme by utilizing random digital optical communication signal as the common drive signal. By utilizing the long-haul optical coherent communication techniques, high-fidelity fiber transmission of the digital drive can be achieved and thus ultra-long-distance synchronization is expected.

View Article and Find Full Text PDF

A fixed support method for cryogenic silicon cavities of ultra-stable lasers for space applications.

Sci Rep

January 2025

School of Physics and Optoelectronic Engineering, Key Laboratory of Gravitational Wave Precision Measurement of Zhejiang Province, Taiji Laboratory for Gravitational Wave Universe, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China.

In this paper, a fixed support method for a cryogenic monocrystalline silicon Fabry-Pérot cavity of an ultra-stable laser for space applications is proposed. Through finite element analysis, the vibration sensitivity at the center of the cavity is below 10E-12/g; the fundamental frequency is 381 Hz; the thermal deformation is compensated by applying a preload force of about 3 N*m for a variation of 300 K to 124 K. Based on these analyses, an equal-mass cavity simulator was machined and mounted.

View Article and Find Full Text PDF

In order to improve the power and energy of water-jet-guided laser, this paper introduces a double beam water-jet-guided laser (DWJL) technology. Based spatially polarized light combination and temporal phase modulation, two lasers are effectively coupled into a water jet with diameter of 100 μm. The maximum output peak power reaches 100 kW and the maximum pulse energy is 4.

View Article and Find Full Text PDF

Pain-Related Responses in Preterm Babies Using Automated and Laser Heel-Lancing Devices.

Creat Nurs

January 2025

Department of Pediatrics, Haeundae Paik Hospital, Inje University, Busan, South Korea.

This study aimed to compare the pain-related behavioral and physiological responses and puncture-related characteristics between automated and laser lancets and examine the correlation between infants' pain-related responses and facial expressions during heel lancing in a neonatal intensive care unit. Pain-related responses were assessed using the Neonatal Infant Pain Scale, heart rate, and oxygen saturation through pulse oximetry. Facial expressions were also analyzed using a facial recognition application.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!