A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Longitudinal follow-up of Riata leads reveals high annual incidence of new conductor externalization and electrical failure. | LitMetric

Background And Purpose: Riata(TM) defibrillation leads are susceptible to conductor externalization. The point prevalence of insulation defect in Riata(TM) leads is up to 33 %, but prospective data concerning incidence of new lead abnormalities are lacking. The purpose of our study was to determine the annual incidence of new conductor externalizations and electrical lead failure.

Methods: A prospective observational study was conducted at a single tertiary center. One hundred forty-one patients were followed over 12 months. A posterior-anterior (PA)/lateral chest x-ray (CXR) with zooming was performed at baseline and at 12 months to screen for conductor externalization. Electrical abnormalities and clinical outcome were also assessed.

Results: The overall incidence of new insulation defects was 8.5 % at 12 months. High-risk leads for new conductor externalization were lead models 1580, 1582, and 1590 with an annual rate of 11.9, 11.1, and 10 %, respectively. New conductor externalizations were three times more common in 8 Fr leads compared to 7 Fr leads. The overall incidence of new electrical dysfunction was 6.4 % at 12 months. Electrical dysfunction was significantly higher in abnormal leads (25 % [3/12], 4.7 % [6/129]; p = 0.03) and mostly driven by high ventricular pacing thresholds. There was no difference in inappropriate shock or failure of high-voltage therapy.

Conclusion: The annual incidence of new insulation defects in Riata(TM) leads is much higher than previously reported. Lead models 1580, 1582, and 1590 are at highest risk for new conductor externalization. Electrical dysfunction in Riata(TM) leads is also much higher than reported and is associated with conductor externalization.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-014-9951-6DOI Listing

Publication Analysis

Top Keywords

conductor externalization
24
annual incidence
12
externalization electrical
12
riatatm leads
12
electrical dysfunction
12
leads
9
conductor
8
incidence conductor
8
conductor externalizations
8
incidence insulation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!