AI Article Synopsis

Article Abstract

The objective of this study is to compare the new and conventional tomotherapy treatment techniques and to evaluate dosimetric differences between them. A dosimetric analysis was performed by comparing planning target volume (PTV) median dose, 95% of PTV dose coverage, Paddick conformity index (CI), homogeneity index (HI), whole-body integral dose, and OAR median doses. The beam on time (BOT) and the effect of different jaw sizes and pitch values was studied. The study results indicated that the PTV dose coverage for all the techniques was comparable. Treatment plans using dynamic jaw reduced OAR doses to structures located at the treatment field edge compared to fixed jaw plans. The HT-3DCRT plans resulted in higher OAR doses to kidney, liver, and lung compared to the other techniques, and TD-IMRT provided the best dose sparing to liver compared to other techniques. Whole-body integral dose differences were found to be insignificant among the techniques. BOT was found to be higher for fixed jaw treatment plan compared to dynamic jaw plan and comparable between all treatment techniques with 5-cm dynamic jaw. In studying effect of jaw size, better OAR sparing and HI were found for 2.5-cm jaw but at the expense of doubling of BOT as compared to 5-cm jaw. There was no significant improvement found in OAR sparing when the pitch value was increased. Increasing the pitch from 0.2 to 0.43, the CI was improved, HI improved only for 5-cm jaw size, and BOT decreased to approximately half of its original time.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1533034614556932DOI Listing

Publication Analysis

Top Keywords

dynamic jaw
12
jaw
10
treatment techniques
8
ptv dose
8
dose coverage
8
whole-body integral
8
integral dose
8
comparable treatment
8
oar doses
8
fixed jaw
8

Similar Publications

Anterior-posterior (A-P) elongation of the palate is a critical aspect of integrated midfacial morphogenesis. Reciprocal epithelial-mesenchymal interactions drive secondary palate elongation that is coupled to the periodic formation of signaling centers within the rugae growth zone (RGZ). However, the relationship between RGZ-driven morphogenetic processes, the differentiative dynamics of underlying palatal bone mesenchymal precursors, and the segmental organization of the upper jaw has remained enigmatic.

View Article and Find Full Text PDF

Objective: Evaluation of the effectiveness of vestibuloplasty according to microhemodynamics and oxygenation in the mucous membrane of the alveolar ridge.

Materials And Methods: To achieve this goal, a clinical and functional study was carried out in the mucous membrane of the alveolar ridge after vestibuloplasty in 80 patients (35 men and 45 women) aged from 18 to 65 years, average age 41.5±1.

View Article and Find Full Text PDF

Background: The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis.

View Article and Find Full Text PDF

Intensive longitudinal sampling enhances subjective data collection by capturing real-time, dynamic inputs in natural settings, complementing traditional methods. This study evaluates the feasibility of using daily self-reported app data to assess clinical improvement among tinnitus patients undergoing treatment. App data from a multi-center randomized clinical trial were analysed using time-series feature extraction and nested cross-validated ordinal regression with elastic net regulation to predict clinical improvement based on the Clinical Global Impression-Improvement scale (CGI-I).

View Article and Find Full Text PDF

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!