Purpose: This study aimed to evaluate (1) the association between implant diameter and marginal bone loss (MBL) of short (6 mm) implants and (2) the survival rates of short implants.

Materials And Methods: Thirty-three 6-mm implants were placed in the mandibles of 16 qualified patients. The selected sites had > 5 mm ridge width and < 9 mm bone height. None of the implant sites required bone augmentation procedures. All implants were uncovered 3 months after placement, and all patients were rehabilitated with 2- or 3-unit implant-supported fixed partial dentures. Standardized periapical films were taken after 24 months of function. Radiographs were digitalized, and MBL was assessed.

Results: For all implants, the mean MBL was 0.17 mm at the point of uncovering. At the 2-year follow-up, all implants were immobile and functional. Implants with 4.2-mm diameters had significantly more MBL (1.95 mm) than wider implants (0.47 mm and 0.35 mm for 5.0-mm and 6.0-mm implants, respectively).

Conclusion: This 2-year study illustrated that short implants are a viable option in selected clinical scenarios. Short implants with wider diameters are preferred because they have less marginal implant bone loss.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.3729DOI Listing

Publication Analysis

Top Keywords

short implants
16
bone loss
12
implants
11
marginal bone
8
bone
5
short
5
implant
4
implant survival
4
survival rate
4
rate marginal
4

Similar Publications

Statement Of Problem: Different factors affect 3-dimensionally (3D) printed resin products. However, evidence on the effect of the print orientation on resin dental devices is lacking.

Purpose: The purpose of this systematic review and meta-analysis was to assess the impact of print orientation on the properties and accuracy of 3D printed implant surgical guides, occlusal devices, clear orthodontic retainers, and aligners.

View Article and Find Full Text PDF

The effective prevention and treatment of anastomotic leakage after intestinal anastomosis for colorectal diseases is still a major clinical challenge. In order to assist intestinal anastomosis healing and avoid anastomotic leakage caused by high tension, low blood supply or infection, we designed a double-layer nanofiber intestinal anastomosis scaffold, which was composed of electrospun PTMC/PHA nanofibers as the main layer, and electrospun PVA/OHA-Gs nanofibers with antibacterial properties as the antibacterial surface layer. This double-layer scaffold has good toughness, its maximum tensile force value could reach 8 N, elongation could reach 400 %, and it has hydrophilic properties, and its contact angle was about 60°.

View Article and Find Full Text PDF

Objective: Somatic variants causing epilepsy are challenging to detect, as they are only present in a subset of brain cells (e.g., mosaic), resulting in low variant allele frequencies.

View Article and Find Full Text PDF

Background: There is growing evidence from laboratory and clinical trials that deep brain stimulation (DBS) at memory associated structures enhances cognitive functions. Best site for memory enhancing-DBS is still unclear. The medial septum (MS), the important modulator of the hippocampal neural network, might be a key target to accomplish therapeutic efficacy in memory impaired patients.

View Article and Find Full Text PDF

Objectives: Re-operations due to material degeneration carry a burden for patients with congenital heart disease (CHD). The study aim was to compare rapid vs. slow degeneration of biomaterials in CHD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!