Vascular air embolism is a rare complication during transurethral surgery. A case of air embolism during holmium laser enucleation of the prostate in a 76-year-old man is presented. During the step of morcellation, the patient's blood pressure suddenly oscillated up and down, and end-tidal CO2 and arterial saturation decreased. Transesophageal and transthoracic echocardiography showed air collection in the right atrium. It was also discovered that incorrect assembly of the tube from the morcellator caused rapid entrainment of air into the vein. Computed tomography and abdominal X-ray showed niveau formation in the femoral vein and air collection in the pelvic retroperitoneal space. The patient recovered with careful observation and was discharged 7 days after the operation with no sequelae. This report is presented to remind urologists of this unusual complication that can occur during holmium laser enucleation of the prostate procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1111/iju.12651DOI Listing

Publication Analysis

Top Keywords

air embolism
12
holmium laser
12
laser enucleation
12
enucleation prostate
12
vascular air
8
embolism holmium
8
air collection
8
air
6
case vascular
4
prostate vascular
4

Similar Publications

Introduction: During a cerebrovascular procedure, diligent care is made to ensure no air is present in lines and connectors. Should air enter the cerebral vasculature, cerebral air emboli can cause worsening neurological outcome or death. This communication outlines how a process change of refrigerating mixed heparin for storage lead to the presence of unintentional air, or off-gassing of the fluid.

View Article and Find Full Text PDF

Carbon dioxide gas emboli is a potentially fatal complication that occurs more frequently during laparoscopic hepatectomy compared to other laparoscopic surgeries. The patient featured in this report had massive gas embolism confirmed by intraoperative transesophageal echocardiography (TEE) that were associated with episodes of severe hypoxemia, hemodynamic instability, and right ventricular failure requiring conversion to open hepatectomy. Abrupt abdominal decompression resulted in massive hemorrhage from a previously undetected defect in the middle hepatic vein.

View Article and Find Full Text PDF

Dynamic EIT technology for real-time non-invasive monitoring of acute pulmonary embolism: a porcine model experiment.

Respir Res

January 2025

Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.

Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.

View Article and Find Full Text PDF

Background: Petroclival meningiomas are still a neurosurgical challenge due to their proximity to cranial nerves and cerebral vasculature along the surgical corridor. The usual extension of large petroclival meningiomas is along the posterior fossa, frequently compromising and displacing adjunct cranial nerves such as the sixth and seventh-eight cranial nerve complex with brainstem compression, causing progressive neurological deficit and severe headache. The goal of sizeable petroclival meningioma surgery treatment is a maximal resection with preservation of neurological function.

View Article and Find Full Text PDF

In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO versus a direct CO blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!