Purpose: To compare the efficacy of 577- and 810-nm subthreshold micropulse laser photocoagulation (SMLP) combined with direct photocoagulation to microaneurysms in diabetic macular edema (DME).

Methods: A prospective nonrandomized interventional case series. Forty-nine consecutive patients (53 eyes) with DME were recruited. In 20/24 (83.3%) eyes, 810-nm SMLP (810-nm MP) to achieve a confluent grid pattern was followed by direct photocoagulation to microaneurysms via a continuous 561-nm wavelength laser. In 21/29 (72.5%) eyes, 577-nm SMLP (577-nm MP) was combined with direct photocoagulation to microaneurysms via the same instrument. Best-corrected visual acuity (BCVA) and central macular thickness (CMT) were examined 1, 2, 3, 6 and 12 months after treatment.

Results: The mean power required for SMLP was lower in the 577-nm than in the 810-nm MP group (204.1 vs. 954.1 mW) (p < 0.0001). Significant reductions in CMT persisted from 3 to 12 months after treatment in all patients (p < 0.01). There were no significant intergroup differences in CMT until 12 months. In both groups, mean BCVA remained stable until 12 months after treatment. Additional treatment for persistent macular edema was performed within 12 months in 4/24 eyes (16.7%) in the 810-nm MP group and 1/29 eyes (3.4%) in the 577-nm MP group.

Conclusion: Either 577-nm MP or 810-nm MP combined with direct photocoagulation for microaneurysm closure reduced DME, maintained visual acuity and reduced the additional treatment rate within 12 months. The 577-nm MP apparatus required less energy for SMLP than the 810-nm MP instrument and was suitable for direct photocoagulation of microaneurysms.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-014-0361-1DOI Listing

Publication Analysis

Top Keywords

direct photocoagulation
24
photocoagulation microaneurysms
16
577-nm 810-nm
12
macular edema
12
combined direct
12
810-nm
8
810-nm subthreshold
8
subthreshold micropulse
8
micropulse laser
8
photocoagulation
8

Similar Publications

Background/objective: Retinal vein occlusion (RVO) is a common, sight-threatening vascular disorder affecting individuals of all ages, with incidence increasing with age. Due to its complex, multifactorial nature, treating RVO remains a clinical challenge. Currently, treatment strategies include laser photocoagulation (especially for branch RVO), anti-VEGF therapies, and intravitreal corticosteroids.

View Article and Find Full Text PDF

Formation of the extrinsic complex (EC) on cell surfaces is the event that triggers the coagulation cascade. Tissue factor (TF) and factor VIIa (FVIIa) form the EC together with factor X (FX) on phosphatidylserine-containing membranes, leading to FX activation by TF:FVIIa. This lipid dependence has made experimental characterization of the EC structure challenging.

View Article and Find Full Text PDF
Article Synopsis
  • PC is a crucial plasma anticoagulant, and mutations in both alleles can lead to a serious condition called neonatal purpura fulminans.
  • The study developed a genome editing approach using engineered activated protein C (APC) to treat congenital PC deficiency by expressing it in mouse liver through adeno-associated virus vectors and CRISPR/Cas9.
  • Results showed that the engineered APC prolonged coagulation time, inhibited harmful thrombus formation, and improved the survival of PC-deficient mice, indicating its potential as a cure for this severe condition.
View Article and Find Full Text PDF

The intricate allostery in factor VIIa: triggering the trigger.

J Thromb Haemost

January 2025

Section for Metabolic Receptology, Novo Nordisk Foundation Center for Basic Metabolic Research, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Article Synopsis
  • * Researchers found out that when FVIIa and TF work together, they change shape and function in complex ways that help the blood clotting process.
  • * Scientists are learning how to control FVIIa activity better, which could help in the future to improve treatments for blood clotting issues.
View Article and Find Full Text PDF

Wet-spinning of carbon nanotube fibers: dispersion, processing and properties.

Natl Sci Rev

October 2024

School of Materials Science and Engineering, Peking University, Beijing 100871, China.

Owing to the intrinsic excellent mechanical, electrical, and thermal properties of carbon nanotubes (CNTs), carbon nanotube fibers (CNTFs) have been expected to become promising candidates for the next-generation of high-performance fibers. They have received considerable interest for cutting-edge applications, such as ultra-light electric wire, aerospace craft, military equipment, and space elevators. Wet-spinning is a broadly utilized commercial technique for high-performance fiber manufacturing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!