Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study.

Eur Spine J

The Department of Spinal Surgery, Zhejiang Spinal Research Center, Second Affiliated Hospital of Wenzhou Medical University, 109# XueYuan Western Road, Wenzhou, 325027, Zhejiang, People's Republic of China,

Published: April 2015

Purpose: To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion.

Methods: CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; θ the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope.

Results: According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully.

Conclusion: Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-014-3663-6DOI Listing

Publication Analysis

Top Keywords

oblique screw
24
percutaneous posterior
20
screw fixation
20
posterior transdiscal
16
transdiscal oblique
16
fixation lateral
16
lateral interbody
16
interbody fusion
12
simulated trajectory
12
trajectory screw
12

Similar Publications

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.

Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).

View Article and Find Full Text PDF

Background: Subtrochanteric proximal femoral fractures are generally treated with cephalomedullary nail fixation. We aimed to compare outcomes of subtrochanteric fracture fixation using a single lag screw (Gamma3 nail, GN) or dual lag screw (INTERTAN nail, IN) device.

Methods: The primary outcome measure was mechanical failure, defined as lag screw cut-out or back-out, nail breakage, or peri-implant fracture.

View Article and Find Full Text PDF

Objective: To explore characteristics, management strategies and preventive measures of fusion device displacement after oblique lateral interbody fusion (OLIF) in treating lumbar lesions.

Methods: The clinical data of 12 patients with fusion device displacement after OLIF for lumbar lesions in 4 medical centers from October 2014 to December 2018 were retrospectively analyzed, including 4 males and 8 females, aged from 53 to 81 years old;2 patients with lumbar disc degeneration, 4 patients with lumbar spinal stenosis, 3 patients with lumbar degenerative spondylolisthesis and 3 patients with lumbar degenerative kyphosis;preoperative dual-energy X-ray bone mineral density (BMD) was detected in 1 patient with T-value > -1 SD, 5 patients with T-value >-1~-2.5 SD, and 6 patients with T-value <-2.

View Article and Find Full Text PDF

Hypertrophic non-union, after an isolated fibular fracture with intact tibia, is an extremely uncommon complication. The aim of the current study is to present an infrequent case of hypertrophic non-union after an isolated fracture in the proximal diaphysis of fibula which was treated surgically. A 23-year-old male patient presented to our hospital with persistent pain on the lateral aspect of his right leg.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!