Purpose: Echocardiography-guided (EG) lead placement at the site of latest left ventricular (LV) mechanical activation improves outcome in patients receiving a cardiac resynchronization therapy (CRT) defibrillator (D). The purpose of this study is to examine whether a strategy of EG LV lead placement equally improves outcome in CRT recipients with wide (≥150 ms) versus intermediate (120-149 ms) QRS duration.
Methods: Patients treated with a CRT-D in the Speckle Tracking Assisted Resynchronization Therapy for Electrode Region (STARTER) prospective, randomized trial (108 EG strategy and 75 routine strategy) were followed to the endpoint of death or first appropriate CRT-D therapy. Of the patients enrolled in STARTER, 115 had QRS ≥ 150 ms and 68 had 120 < QRS ≤ 149 ms.
Results: Over a mean follow-up period of 3.7 ± 2.1 years, 62 (33 %) patients died and 40 (22 %) received appropriate CRT-D therapy. Compared to patients with QRS ≥ 150 ms, patients with intermediate QRS had meaningfully worse survival free from ICD therapy (HR = 1.48, p = 0.056). CRT-D therapy-free survival was significantly worse in patients with intermediate QRS duration randomized to the routine LV lead placement strategy, compared to patients with intermediate QRS duration randomized to the EG LV lead placement strategy or patients with wide QRS duration regardless of LV implantation strategy (HR = 2.08, 95 % confidence interval = 1.21-3.56, P = 0.008). This finding was independent in type of cardiomyopathy.
Conclusion: A strategy of EG LV lead placement improves survival free from defibrillator therapy in patients with QRS between 120-149 ms to levels comparable to those of patients with QRS ≥ 150 ms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-014-9953-4 | DOI Listing |
J Urol
January 2025
Department of Population Health, NYU Grossman School of Medicine, New York, New York.
Purpose: We aimed to determine whether implementation of clinical decision support (CDS) tool integrated into the electronic health record (EHR) of a multi-site academic medical center increased the proportion of patients with American Urological Association (AUA) "high risk" microscopic hematuria (MH) who receive guideline concordant evaluations.
Materials And Methods: We conducted a two-arm cluster randomized quality improvement project in which 202 ambulatory sites from a large health system were randomized to either have their physicians receive at time of test results an automated CDS alert for patients with 'high-risk' MH with associated recommendations for imaging and cystoscopy (intervention) or usual care (control). Primary outcome was met if a patient underwent both imaging and cystoscopy within 180 days from MH result.
Mol Biol Rep
January 2025
Department of Biomedical Laboratory Science and Management, Vidyasagar University, Midnapore, West Bengal, 721102, India.
Background: Rising antimicrobial resistance (AMR) is an acute public health emergency impeding the clinical efficacy of surgical interventions. Biliary stent placement is one of the routine surgical procedures that rarely lead to infections that are empirically managed by broad-spectrum β-lactams and fluoroquinolones. Critical priority pathogens, such as carbapenem-resistant Escherichia coli challenge treatment outcomes and infection prevention.
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
January 2025
Division of Maxillofacial Surgery, Department of Surgery, AZ Sint-Jan Brugge AV, Bruges, Belgium; Oral and Maxillofacial Surgery Unit, Division of Surgery, Barzilai Medical Center, Affiliated to Ben-Gurion University of the Negev, Ashkelon, Israel.
Antegonial notching can occur after bilateral sagittal split osteotomy (BSSO) and may lead to unpleasant aesthetic outcomes in both young and older patients. This clinical study presents a new concept to potentially overcome this problem and describes the workflow. Beta-tricalcium phosphate patient-specific gap implants (β-TCP gap-PSIs) are biocompatible and resorbable bone grafts that are placed in the space of the osteotomy gap during orthognathic procedures; they are virtually planned and printed in 3D.
View Article and Find Full Text PDFJ Glaucoma
January 2025
Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore.
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.
View Article and Find Full Text PDFCase Rep Gastrointest Med
January 2025
Gastroenterology and Hepatology Unit, The Canberra Hospital, Australian Capital Territory, Canberra, Australia.
We present a case of an 80-year-old female who presented with chest pain, vomiting and night sweats a few weeks post thoracic endovascular aortic aneurysm repair (TEVAR). A computed tomography (CT) scan demonstrated a type 1B endoleak for which she underwent a repeat TEVAR. Postoperatively, she developed fever, dysphagia, haematemesis and melaena.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!