Objective: To optimize a radial turbo spin-echo sequence for motion-robust morphological lung magnetic resonance imaging (MRI) in free respiration.
Materials And Methods: A versatile multi-shot radial turbo spin-echo (rTSE) sequence is presented, using a modified golden ratio-based reordering designed to prevent coherent streaking due to data inconsistencies from physiological motion and the decaying signal. The point spread function for a moving object was simulated using a model for joint respiratory and cardiac motion with a concomitant T2 signal decay and with rTSE acquisition using four different reordering techniques. The reordering strategies were compared in vivo using healthy volunteers and the sequence was tested for feasibility in two patients with lung cancer and pneumonia.
Results: Simulations and in vivo measurements showed very weak artifacts, aside from motion blur, using the proposed reordering. Due to the opportunity for longer scan times in free respiration, a high signal-to-noise ratio (SNR) was achieved, facilitating identification of the disease as compared to standard half-Fourier-acquisition single-shot turbo spin-echo (HASTE) scans. Additionally, post-processing allowed modifying the T2 contrast retrospectively, further improving the diagnostic fidelity.
Conclusion: The proposed radial TSE sequence allowed for high-resolution imaging with limited obscuring artifacts. The radial k-space traversal allowed for versatile post-processing that may help to improve the diagnosis of subtle diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10334-014-0468-x | DOI Listing |
Magn Reson Med
January 2025
Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.
Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.
Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.
Curr Oncol
January 2025
Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.
View Article and Find Full Text PDFJ Clin Neurosci
January 2025
Department of Neurological Surgery and Rosa Ella Burkhardt Brain Tumor & Neuro-Oncology Center, Cleveland Clinic, Cleveland, OH, USA; Cleveland Clinic Lerner College of Medicine of Case Western Reserve University. Electronic address:
Background And Objective: Radiosurgery can serve as a primary, adjuvant, or salvage treatment modality for cavernous sinus tumors (CST), providing high tumor control. However, particularly with cavernous sinus expansion, there may be insufficient distance from the optic apparatus to perform radiosurgery safely. The internal carotid artery adjacent to the distal dural ring (ICAddr), when enhancing similarly to the CST, can be difficult to delineate, and can lead to over-contouring of target volume near the optic nerve and therefore increasing the risk of radiation-induced optic toxicity.
View Article and Find Full Text PDFEur Radiol
January 2025
Neuroradiology Section, Department of Radiology, Hospital Universitario 12 de Octubre, Madrid, Spain.
Objectives: Brain metastases are the most common intracranial malignancy in adults, and their detection is crucial for treatment planning. Post-contrast 3D T1 gradient-recalled echo (GRE) sequences are commonly used for this purpose, but contrast-enhanced 3D T1 turbo spin-echo (TSE) sequences with motion-sensitized driven-equilibrium (MSDE) technique ("black blood") may offer improved detection. This study aimed to compare the effectiveness of contrast-enhanced 3D black blood sequences to standard 3D T1 GRE sequences in detecting brain metastases on a 1.
View Article and Find Full Text PDFImmun Inflamm Dis
January 2025
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Objective: This study aimed to evaluate the activity of extraocular muscles (EOMs) in patients with thyroid-associated ophthalmopathy (TAO) using turbo spin echo imaging. By analyzing tissue heterogeneity, apparent diffusion coefficient (ADC) histogram analysis offers enhanced insights into edema within the EOMs.
Methods: Eighty-eight patients with TAO were retrospectively evaluated and allocated into active (n = 24, clinical activity score [CAS] ≥ 3) and inactive (n = 64, CAS < 3) groups.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!