Enhanced performance of methamphetamine lateral flow cassettes using an electronic lateral flow reader.

J Occup Environ Hyg

a Division of Applied Research and Technology, National institute for Occupational Safety and Heath, United States Centers for Disease Control and Prevention, Cincinnati , Ohio.

Published: July 2015

Surface contamination from methamphetamine in meth labs continues to be a problem. We had previously developed a lateral flow assay cassette for field detection of methamphetamine contamination that is commercially available and has been used by a number of groups to assess contamination. This cassette uses the complete disappearance of the test line as an end point for detection of 50 ng/100 cm2 of methamphetamine contamination for surface sampling with cotton swabs. In the present study, we further evaluate the response of the cassettes using an electronic lateral flow reader to measure the intensities of the test and control lines. The cassettes were capable of detecting 0.25 ng/ml for calibration solutions. For 100 cm2 ceramic tiles that were spiked with methamphetamine and wiped with cotton-tipped wooden swabs wetted in assay/sampling buffer, 1 ng/tile was detected using the reader. Semi-quantitative results can be produced over the range 0-10 ng/ml for calibration solutions and 0-25 ng/tile for spiked tiles using either a 4-parameter logistic fit of test line intensity versus concentration or spiked mass or the ratio of the control line to the test line intensity fit to concentration or spiked mass. Recovery from the tiles was determined to be about 30% using the fitted curves. Comparison of the control line to the test line was also examined as a possible visual detection end point and it was found that the control line became more intense than the test line at 0.5 to 1 ng/ml for calibration solutions or 1 to 2 ng/tile for spiked tiles. Thus the lateral flow cassettes for methamphetamine have the potential to produce more sensitive semi-quantitative results if an electronic lateral flow reader is used and can be more sensitive for detection if the comparison of the control line to the test line is used as the visual end point.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4545259PMC
http://dx.doi.org/10.1080/15459624.2014.935782DOI Listing

Publication Analysis

Top Keywords

lateral flow
24
electronic lateral
12
flow reader
12
ng/ml calibration
12
calibration solutions
12
control test
12
flow cassettes
8
cassettes electronic
8
methamphetamine contamination
8
ng/tile spiked
8

Similar Publications

Staphylococcus pseudintermedius is a global animal pathogen. Traditional identification methods are time-consuming necessitating a more efficient approach. This study validated and enhanced the loop-mediated isothermal amplification (LAMP) technique by integration it with a lateral flow dipstick (LFD) assay for the detection of S.

View Article and Find Full Text PDF

A Chromatography Test Strip of Exonuclease III-Amplified Aptamer for Rapid Identification of Prorocentrum minimum.

Mar Biotechnol (NY)

January 2025

School of Marine Science and Technology, Harbin Institute of Technology (Weihai), Wenhua West Road, 2#, Weihai, 264209, People's Republic of China.

Recently, the scale and frequency of harmful algae blooms (HABs) have gradually increased, posing a serious threat to human health, marine ecosystems and economic development. For early warning, a method is required that can quickly detect and monitor microalgae. It is proposed to use aptamer targeted to Prorocentrum minimum, along with exonuclease III (Exo III), gold nanoparticles, target single-stranded DNA and hairpin structure probe to construct a new method, i.

View Article and Find Full Text PDF

The widespread adoption and commercialization of lateral flow assays (LFAs) for clinical diagnosis have been hindered by limitations in sensitivity, specificity, and the absence of quantitative data. To address these challenges, we developed aptamer-architectured gold nanoparticles as nanozymes that catalytically convert -phenylenediamine (PPD) into Bandrowski's base (BB), thereby amplifying signal strength and sensitivity. The physiochemical properties of the nanozymes were characterized and their specific binding efficiency was demonstrated using experimental studies.

View Article and Find Full Text PDF

Background: Radiotherapy is the primary treatment modality for most head and neck cancers (HNCs). Despite the addition of chemotherapy to radiotherapy to enhance its tumoricidal effects, almost a third of HNC patients suffer from locoregional relapses. Salvage therapy options for such recurrences are limited and often suboptimal, partly owing to divergent tumor and microenvironmental factors underpinning radioresistance.

View Article and Find Full Text PDF

Development of a duplex loop-mediated isothermal amplification together with lateral flow dipstick assay for the detection and discrimination of parasitic infections in chickens between cestodes belonging to genus Raillietina and trematodes in family Echinostomatidae.

Res Vet Sci

January 2025

Applied Parasitology Research Laboratory, Department of Biology, Faculty of Science, Srinakharinwirot University, Bangkok 10110, Thailand; Research and innovation unit for diagnosis of medical and veterinary important parasites, Faculty of Science, Srinakharinwirot University, Bangkok 10110, Thailand. Electronic address:

Most poultry farming that has been conducted by smallholders in Thailand are free-range and housing systems, which have risks of parasitic infection from the environment, particularly from tapeworms in the genus Raillietina and trematodes in the family Echinostomatidae. These have become important health problems in the poultry industry, causing low feed conversion ratios and leading to the loss of economic value. Our objective was to develop and validate a molecular technique based on duplex loop-mediated isothermal amplification (LAMP) together with lateral flow dipstick (LFD) assay for discriminating the infections between the genus Raillietina (R.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?