Background: The inherently complex three-dimensional morphology of both the pelvis and acetabulum create difficulties in accurately determining acetabular orientation. Our objectives were to develop a reliable and accurate methodology for determining three-dimensional acetabular orientation and to utilize it to describe relevant characteristics of a large population of subjects without apparent hip pathology.
Methods: High-resolution computed tomography studies of 200 patients previously receiving pelvic scans for indications not related to orthopaedic conditions were selected from our institution's database. Three-dimensional models of each osseous pelvis were generated to extract specific anatomical data sets. A novel computational method was developed to determine standard measures of three-dimensional acetabular orientation within an automatically identified anterior pelvic plane reference frame. Automatically selected points on the osseous ridge of the acetabulum were used to generate a best-fit plane for describing acetabular orientation.
Results: Our method showed excellent interobserver and intraobserver agreement (an intraclass correlation coefficient [ICC] of >0.999) and achieved high levels of accuracy. A significant difference between males and females in both anteversion (average, 3.5°; 95% confidence interval [CI], 1.9° to 5.1° across all angular definitions; p < 0.0001) and inclination (1.4°; 95% CI, 0.6° to 2.3° for anatomic angular definition; p < 0.002) was observed. Intrapatient asymmetry in anatomic measures showed bilateral differences in anteversion (maximum, 12.1°) and in inclination (maximum, 10.9°).
Conclusions: Significant differences in acetabular orientation between the sexes can be detected only with accurate measurements that account for the entire acetabulum. While a wide range of interpatient acetabular orientations was observed, the majority of subjects had acetabula that were relatively symmetrical in both inclination and anteversion.
Clinical Relevance: A highly accurate and reproducible method for determining the orientation of the acetabulum's aperture will benefit both surgeons and patients, by further refining the distinctions between normal and abnormal hip characteristics. Enhanced understanding of the acetabulum could be useful in the diagnostic, planning, and execution stages for surgical procedures of the hip or in advancing the design of new implant systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.L.01141 | DOI Listing |
Arthroplast Today
February 2025
Department of Radiology, Montefiore Medical Center, Bronx, NY.
Background: Periprosthetic hip dislocation after total hip arthroplasty is a devastating postoperative complication. It is often associated with suboptimal orientation of the acetabular component, characterized by the acetabular abduction and anteversion angles obtained from anteroposterior pelvic radiographs. We introduce a novel automated web tool to streamline the subjective and lengthy process of this manual measurement and compare it to manual human measurements.
View Article and Find Full Text PDFHip Int
January 2025
Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.
Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.
Surg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFJ Hum Evol
January 2025
Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO 65212, USA.
Hominin pelvic form differs dramatically from that of other primates by having more laterally facing iliac blades, a wider sacrum, and a larger, transversely broad pelvic inlet. The orientation of the acetabulum may also differ, plausibly related to differences in load transmission during upright posture and habitual bipedal locomotion, which may, in turn, affect overall pelvic geometry. We compared acetabular orientation in humans, a phylogenetically broad sample of extant anthropoid primates, and fossil hominins including Australopithecus afarensis (A.
View Article and Find Full Text PDFArthroplasty
January 2025
Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy.
Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.