Comparison of predictor approaches for longitudinal binary outcomes: application to anesthesiology data.

PeerJ

Faculty of Medicine, Department of Biostatistics and Medical Informatics, Akdeniz University, Antalya , Turkey.

Published: November 2014

Longitudinal data with binary repeated responses are now widespread among clinical studies and standard statistical analysis methods have become inadequate in the answering of clinical hypotheses. Instead of such conventional approaches, statisticians have started proposing better techniques, such as the Generalized Estimating Equations (GEE) approach and Generalized Linear Mixed Models (GLMM) technique. In this research, we undertook a comparative study of modeling binary repeated responses using an anesthesiology dataset which has 375 patient data with clinical variables. We modeled the relationship between hypotension and age, gender, surgical department, positions of patients during surgery, diastolic blood pressure, pulse, electrocardiography and doses of Marcain-heavy, chirocaine, fentanyl, and midazolam. Moreover, parameter estimates between the GEE and the GLMM were compared. The parameter estimates, except time-after, Marcain-Heavy, and Fentanyl from the GLMM, are larger than those from GEE. The standard errors from the GLMM are larger than those from GEE. GLMM appears to be more suitable approach than the GEE approach for the analysis hypotension during spinal anesthesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4217193PMC
http://dx.doi.org/10.7717/peerj.648DOI Listing

Publication Analysis

Top Keywords

binary repeated
8
repeated responses
8
gee approach
8
parameter estimates
8
gee glmm
8
glmm larger
8
larger gee
8
gee
5
glmm
5
comparison predictor
4

Similar Publications

Background: This retrospective study aimed to investigate the relationships between the radiographic features of impacted maxillary canines (IMCs) and traction duration and the factors affecting treatment success.

Methods: Pre-treatment panoramic radiographs and patient records of 121 consecutive patients with IMCs were analyzed. The measurements included the angle of the IMC with the midline (α-angle), the horizontal position of the IMC relative to the adjacent teeth (S-Sector), the distance from the IMC to the occlusal plane (d-distance), the apex position of the IMC (A), and the vertical height of the IMC relative to the adjacent lateral tooth (V).

View Article and Find Full Text PDF

Background: The COVID-19 pandemic disproportionately affected migrant populations in Japan, including Vietnamese migrants, who faced distinct challenges in accessing healthcare compared to native Japanese citizens. These challenges, exacerbated by the structural complexities of Japan's healthcare system during the pandemic, likely influenced their subjective health perceptions. Nevertheless, studies on Vietnamese migrants' difficulties in healthcare access during the pandemic and their perceived health perceptions are lacking.

View Article and Find Full Text PDF

Optimizing convolutional neural networks for Chronic Obstructive Pulmonary Disease detection in clinical computed tomography imaging.

Comput Biol Med

December 2024

Department of Diagnostic and Interventional Radiology, School of Medicine and Health, Klinikum rechts der Isar, Technical University of Munich, Munich, 81675, Bavaria, Germany; Institute for Advanced Study, Technical University of Munich, Garching, 85748, Bavaria, Germany.

We aim to optimize the binary detection of Chronic Obstructive Pulmonary Disease (COPD) based on emphysema presence in the lung with convolutional neural networks (CNN) by exploring manually adjusted versus automated window-setting optimization (WSO) on computed tomography (CT) images. 7194 contrast-enhanced CT images (3597 with COPD; 3597 healthy controls) from 78 subjects were selected retrospectively (01.2018-12.

View Article and Find Full Text PDF

The quantitative detection of HO is of great significance for preventing the occurrence of diseases. In this work, an electrochemical biosensor for detecting HO was constructed through a step-by-step modification method. The PDEA-HRP/MXene/PG biosensor (PDEA = poly(N,N-dimethyl acrylamide), HRP = horseradish peroxidase, PG = pyrolytic graphite) was prepared with two-dimensional metal carbide (MXene) nano materials as the inner layer and PDEA-HRP hydrogel as the outer layer for the detection of HO.

View Article and Find Full Text PDF

Quantitative pupillometry has been proposed as an objective means to diagnose acute sports-related concussion (SRC). To assess the diagnostic accuracy of a smartphone-based quantitative pupillometer in the acute diagnosis of SRC. Division I college football players had baseline pupillometry including pupillary light reflex (PLR) parameters of maximum resting diameter, minimum diameter after light stimulus, percent change in pupil diameter, latency of pupil constriction onset, mean constriction velocity, maximum constriction velocity, and mean dilation velocity using a smartphone-based app.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!